Author: Macha, K.
Paper Title Page
MOOAC03 Superconducting Resonators Development for the FRIB and ReA Linacs at MSU: Recent Achievements and Future Goals 61
 
  • A. Facco
    INFN/LNL, Legnaro (PD), Italy
  • E.C. Bernard, J. Binkowski, C. Compton, J.L. Crisp, L.J. Dubbs, K. Elliott, A. Facco, L.L. Harle, M. Hodek, M.J. Johnson, D. Leitner, M. Leitner, I.M. Malloch, S.J. Miller, R. Oweiss, J. Popielarski, L. Popielarski, K. Saito, J. Wei, J. Wlodarczak, Y. Xu, Y. Zhang, Z. Zheng
    FRIB, East Lansing, Michigan, USA
  • A. Burrill, G.K. Davis, K. Macha, A.V. Reilly
    JLAB, Newport News, Virginia, USA
 
  Funding: This material is based upon work supported by the U.S. Department of Energy Office of Science under Cooperative Agreement DE-SC0000661
The superconducting driver and post-accelerator linacs of the FRIB project, the large scale radioactive beam facility under construction at MSU, require the construction of about 400 low-beta Quarter-wave (QWR) and Half-wave resonators (HWR) with four different optimum velocities. 1st and 2nd generation prototypes of β=0.041 and 0.085 QWRs and β=0.53 HWRs have been built and tested, and have more than fulfilled the FRIB and ReA design goals. The present cavity surface preparation at MSU allowed production of low-beta cavities nearly free from field emission. The first two cryostats of β=0.041 QWRs are now in operation in the ReA3 linac. A 3rd generation design of the FRIB resonators allowed to further improve the cavity parameters, reducing the peak magnetic field in operation and increasing the possible operation gradient , with consequent reduction of the number of required resonators. The construction of the cavities for FRIB, which includes three phases for each cavity type (development, pre-production and production runs) has started. Cavity design, construction, treatment and performance will be described and discussed.
Michigan State University designs and establishes FRIB as a DOE Office of Science National User Facility in support of the mission of the Office of Nuclear Physics.
 
slides icon Slides MOOAC03 [4.009 MB]  
 
WEPPC038 Status of the Short-Pulse X-ray Project at the Advanced Photon Source 2292
 
  • A. Nassiri, N.D. Arnold, T.G. Berenc, M. Borland, B. Brajuskovic, D.J. Bromberek, J. Carwardine, G. Decker, L. Emery, J.D. Fuerst, A.E. Grelick, D. Horan, J. Kaluzny, F. Lenkszus, R.M. Lill, J. Liu, H. Ma, V. Sajaev, T.L. Smith, B.K. Stillwell, G.J. Waldschmidt, G. Wu, B.X. Yang, Y. Yang, A. Zholents
    ANL, Argonne, USA
  • J.M. Byrd, L.R. Doolittle, G. Huang
    LBNL, Berkeley, California, USA
  • G. Cheng, G. Ciovati, P. Dhakal, G.V. Eremeev, J.J. Feingold, R.L. Geng, J. Henry, P. Kneisel, K. Macha, J.D. Mammosser, J. Matalevich, A.D. Palczewski, R.A. Rimmer, H. Wang, K.M. Wilson, M. Wiseman
    JLAB, Newport News, Virginia, USA
  • Z. Li, L. Xiao
    SLAC, Menlo Park, California, USA
 
  Funding: Work supported by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences, under Contract No. DE-AC02-06CH11357.
The Advanced Photon Source Upgrade (APS-U) Project at Argonne will include generation of short-pulse x-rays based on Zholents’* deflecting cavity scheme. We have chosen superconducting (SC) cavities in order to have a continuous train of crabbed bunches and flexibility of operating modes. In collaboration with Jefferson Laboratory, we are prototyping and testing a number of single-cell deflecting cavities and associated auxiliary systems with promising initial results. In collaboration with Lawrence Berkeley National Laboratory, we are working to develop state-of-the-art timing, synchronization, and differential rf phase stability systems that are required for SPX. Collaboration with Advanced Computations Department at Stanford Linear Accelerator Center is looking into simulations of complex, multi-cavity geometries with lower- and higher-order modes waveguide dampers using ACE3P. This contribution provides the current R&D status of the SPX project.
* A. Zholents et al., NIM A 425, 385 (1999).
 
 
WEPPR094 Large Volume Resonant Microwave Discharge for Plasma Cleaning of a CEBAF 5-Cell Srf Cavity 3156
 
  • S. Ahmed, K. Macha, J.D. Mammosser
    JLAB, Newport News, Virginia, USA
  • M. Nikolić, S. Popović, J. Upadhyay, L. Vušković
    ODU, Norfolk, Virginia, USA
 
  Funding: Authored by Jefferson Science Associates, LLC under U.S. DOE Contract No. DE-AC05-06OR23177. The U.S.
We report preliminary results on plasma generation in a 5-cell CEBAF SRF cavity for the application of cavity interior surface cleaning. CEBAF currently has ~300 of these five cell cavities installed in the JLab accelerator which are mostly limited by cavity surface contamination. The development of an in-situ cavity surface cleaning method utilizing a resonant microwave discharge could lead to significant performance improvement. This microwave discharge is currently being used for set of plasma cleaning procedures targeted to the removal of various organic, metal and metal oxide impurities. These contaminants are responsible for the increase of surface resistance and the reduction of RF performance in installed cavities. CEBAF five cell cavity volume is ~ 0.5 m2, which places the discharge in the category of large-volume plasmas. Our preliminary study includes microwave breakdown and optical spectroscopy, which was used to define the operating pressure range and the rate of removal of organic impurities.