Author: Ishii, K.
Paper Title Page
THPPP004 Design and Test of Injection Kicker Magnets for the JPARC Main Ring 3728
 
  • K. Fan, S. Fukuoka, K. Ishii, H. Matsumoto, H. Someya, T. Sugimoto, T. Toyama
    KEK, Ibaraki, Japan
 
  The present injection kicker magnets of the JPARC main ring consists of three transmission type kickers. To overcome the operational problems, four lumped inductance kicker magnets have been developed for the simplicity and the high reliability. The tight requirements on the rise and fall time create difficulties for the new design. Magnetic field measurements, coupling impedance measurements and have been carried out. The measurement results show that the new kicker magnets can satisfy the requirements of beam injection.