Author: Delrieux, M.
Paper Title Page
THPHA135 Wall Current Monitor Using PXI and LabVIEW at CERN 1699
 
  • C. Charrondière, M. Delrieux, R. Limpens
    CERN, Geneva, Switzerland
 
  The new data acquisition system for the PS ring wall current monitors installed in the PS is able to perform higher frequency measurements of a beam bunch up to a frequency of 2.7 GHz. This is an important improvement, since the oscillating signal within the bandwidth 500-700 MHz, is related to losses of a beam bunch. The losses can be reduced by measuring the frequency and classifying the cause of the oscillations. The PXI-5661 is used to carry out spectral analysis of this signal. The acquisition is performed on a PXI running LabVIEW Real-Time and synchronized using a trigger from the accelerator timing system.  
poster icon Poster THPHA135 [2.390 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-ICALEPCS2017-THPHA135  