JACoW logo

Joint Accelerator Conferences Website

The Joint Accelerator Conferences Website (JACoW) is an international collaboration that publishes the proceedings of accelerator conferences held around the world.


RIS citation export for THCPA04: Development of a Safety Classified System with LabView and EPICS

TY - CONF
AU - Haquin, C.H.
AU - Anger, P.
AU - Deroy, D.J.C.
AU - Normand, G.
AU - Pillon, F.
AU - Savalle, A.
ED - Schaa, Volker RW
ED - Costa, Isidre
ED - Fernández, David
ED - Matilla, Óscar
TI - Development of a Safety Classified System with LabView and EPICS
J2 - Proc. of ICALEPCS2017, Barcelona, Spain, 8-13 October 2017
C1 - Barcelona, Spain
T2 - International Conference on Accelerator and Large Experimental Control Systems
T3 - 16
LA - english
AB - The Spiral2 linear accelerator will drive high intensity beams, up to 5 mA and 200 kW at linac exit. In tuning phase, or when not used by the experimental areas, the beam will be stopped in a dedicated beam dump. To avoid excessive activation of this beam dump, in order to allow human intervention, a safety classified system had been designed to integrate the number of particles dropped in it within each 24 hours time frame. For each kind of beam, a threshold will be defined and as soon as the threshold is reached a beam cut-off will be sent to the machine protection system. This system, called SLAAF: System for the Limitation of the Activation of the beam dump (Arret Faisceau in French) rely on LabView and EPICS (Experimental Physics and Industrial Control) technology. This paper will describe the specification and development processes and how we dealt to meet both functional and safety requirements using two technologies not commonly used for safety classified systems.
PB - JACoW
CP - Geneva, Switzerland
SP - 1221
EP - 1223
KW - ion
KW - EPICS
KW - controls
KW - LabView
KW - interface
DA - 2018/01
PY - 2018
SN - 978-3-95450-193-9
DO - 10.18429/JACoW-ICALEPCS2017-THCPA04
UR - http://jacow.org/icalepcs2017/papers/thcpa04.pdf
ER -