Paper |
Title |
Other Keywords |
Page |
TUPF01 |
NSLS-II RF Beam Position Monitor- System Test and Integration |
storage-ring, controls, hardware, status |
289 |
|
- D. Padrazo, A. Caracappa, W.X. Cheng, C. Danneil, A.J. Della Penna, K. Ha, M.A. Maggipinto, J. Mead, O. Singh, K. Vetter
BNL, Upton, Long Island, New York, USA
|
|
|
The NSLS-II Synchrotron Light Source is a 3 GeV electron storage ring currently in the early stages of commissioning at Brookhaven National Laboratory. The RF Beam Position Monitors (RF BPM) are one of the key diagnostics systems required for a successful and efficient commissioning. There are more than 250 RF BPM installed in the injector and the storage ring. Each RF BPM was fully tested, first under laboratory environment and then after installation, utilizing built in pilot tone signal source. These successful tests provided a solid base for the integrity of RF BPM systems, prior to the start of beam commissioning. This paper will describe tests performed and results of system integration.
|
|
|
Poster TUPF01 [1.068 MB]
|
|
Export • |
reference for this paper to
※ LaTeX,
※ Text,
※ IS/RefMan,
※ EndNote (xml)
|
|
|