Paper | Title | Page |
---|---|---|
MOPF31 | Overview of Beam Instrumentation Activities for SwissFEL | 119 |
|
||
SwissFEL will provide users with brilliant X-ray pulses in 2017. A comprehensive suite of diagnostics is needed for the initial commissioning, for changes to the operating point, and for feedbacks. The development of instrumentation for SwissFEL is well underway, and solutions have been identified for most diagnostics systems. I will present here an overview of the instrumentation for SwissFEL, and give details on some recent developments. | ||
![]() |
Poster MOPF31 [4.418 MB] | |
Export • | reference for this paper to ※ LaTeX, ※ Text, ※ IS/RefMan, ※ EndNote (xml) | |
TUPF07 | FLASH Undulator BPM Commissioning and Beam Characterization Results | 315 |
|
||
Recently, the commissioning of FLASH2 has started, a new soft X-ray FEL undulator line at the DESY FLASH facility. In the FLASH2 undulator intersections, the beam positions are measured by 17 cavity beam position monitor (CBPM) pick-ups and electronics* developed for the European XFEL (E-XFEL). In addition four CBPMs are available at FLASH1 for test and development. The new CBPM system enables an unprecedented position and charge resolution at FLASH, thus allowing further analysis and optimization of the FLASH beam quality and overall accelerator performance. Results of first beam measurements as well as correlations with other FLASH diagnostics systems are reported.
* M. Stadler et al., “Low-Q Cavity BPM Electronics for E-XFEL, FLASH-2 and SwissFEL”, this conference. |
||
![]() |
Poster TUPF07 [1.112 MB] | |