Author: Arinaga, M.
Paper Title Page
TUPD22 Beam Loss Monitor at SuperKEKB 459
 
  • H. Ikeda, M. Arinaga, J.W. Flanagan, H. Fukuma, M. Tobiyama
    KEK, Ibaraki, Japan
 
  We will use beam loss monitors for protection of the hardware of SuperKEKB against the unexpected sudden beam loss. The sensors are ion chambers and PIN photo-diodes. The loss monitor system gives an important trigger for the beam abort system. We can optimize the threshold of the abort trigger by checking the beam information at each abort moment. This paper explains the overall system of the SuperKEKB beam loss monitors including the damping ring.  