TY - CPAPER AU - Naito, T. AU - Mitsuhashi, T.M. TI - YAG:Ce Screen Monitor Using a Gated CCD Camera J2 - Proc. of IBIC2014 AB - Due to its good spatial resolution, the YAG:Ce screen monitor is often used for small beam profile measurement in the Linac and beam transport line. We constructed a high-resolution YAG:Ce screen monitor at KEK-ATF2 for the observation of small size beams a. We tested two types of screens, one is powder YAG:Ce and the other is single crystal YAG:Ce. Both screens have 50μm thickness. To escape from strong COTR, we applied delayed timing of the gate for the CCD camera. A microscope having a spatial resolution of 6μm was set outside of a vacuum chamber to observe the scintillation light from the YAG:Ce screen. The results of the difference between the two screens, the camera performance with delayed gate, and the optical performance of the microscope will be presented in this session. PB - JACoW CY - Geneva, Switzerland SP - 426 EP - 429 KW - timing KW - emittance KW - radiation KW - synchrotron-radiation KW - collider DA - 2014/10 PY - 2014 SN - 978-3-95450-141-0 UR - http://jacow.org/IBIC2014/papers/tupd08.pdf ER -