TY - CPAPER AU - Lensch, T. AU - Delfs, A. AU - Gharibyan, V. AU - Krouptchenkov, I. AU - Nölle, D. AU - Pelzer, M. AU - Tiessen, H. AU - Werner, M. AU - Wittenburg, K. TI - Wire Scanner Installation into the MicroTCA Environment for the European XFEL J2 - Proc. of IBIC2014 AB - The European XFEL (E-XFEL) is a 4th generation synchrotron radiation source currently under construction in Hamburg. The 17.5 GeV superconducting accelerator will provide photons simultaneously to several user stations [*]. For the transverse beam profile measurement in the high energy sections Wire Scanners are used as an essential part of the accelerator diagnostic system, providing the tool to measure small beam size in an almost nondestructive manner. The scanners will be operated in a fast mode, starting from a trigger the wire will be accelerated to 1 m/s and hitting about 100 bunches out of the long bunch train of E-XFEL within a single macropulse. Slow scans with single bunches are also possible. In the first stage 12 stations are planned to be equipped with Wire Scanners where each station consists of two motion units (horizontal and vertical plane). The new concept uses linear servo motors for the motion of the wires and a new mechanical design has been developed at DESY [**]. This paper describes the electronics developments for the motion part of these Wire Scanners and the integration into the MicroTCA environment. PB - JACoW CY - Geneva, Switzerland SP - 73 EP - 76 KW - detector KW - controls KW - interface KW - timing KW - electronics DA - 2014/10 PY - 2014 SN - 978-3-95450-141-0 UR - http://jacow.org/IBIC2014/papers/mopf13.pdf ER -