Author: Zhang, J.
Paper Title Page
MOPF02 The Wire Scanner Control Sytem for C-ADS Injector-II 197
 
  • M. Li, X.C. Kang, R.S. Mao, J.X. Wu, Y.J. Yuan, J. Zhang, Y. Zhang, G. Zhu
    IMP, Lanzhou, People's Republic of China
 
  The C-ADS project is a strategic plan to solve the nuclear waste problem and the resource problem for nuclear power plants in China. The first step of this project is to build two 5-MeV test CW linac. The institute of Modern physics (IMP) is in charge of designing one of them. In order to measure the beam profile in this linac, a wire scanner system was designed and tested. In this paper, the mechanical design and control system of this wire scanner system are introduced. A real-time, closed loop control system is being developed and tested for more repeatable and accurate positioning of beam sense wires. All of the electronic and computational duties are handled in one the National Instruments compact RIO real-time chassis with a Field-Programmable Gate Array (FPGA). The beam test result of this system in IMP 320 KV beam line was present. The test result of this system and the measured beam profile result are discussed in this paper.