Author: Ren, G.
Paper Title Page
TUPC47 Simulation for Radiation Field Caused by Beam Loss of C-ADS Injector II 489
 
  • G. Ren, W. Li, Y. Li
    USTC/NSRL, Hefei, Anhui, People's Republic of China
  • M. Zeng
    Tsinghua University, Beijing, People's Republic of China
 
  CADS is a Chinese ADS(Accelerator Driven Sub-critical System) project. Its injector is a high current, full superconducting proton accelerator. For such a facility, a BLM system is necessary, especially in low energy segments. This paper presents some basic simulation for 10MeV proton by Monte Carlo program FLUKA, as well as the distributions we got about different secondary particles in three aspects: angular, energy spectrum and current. These results are helpful to select the detector type and its location, determine its dynamic range matching different requirements for both fast and slow beam loss. This paper also analyzes the major impact of the background, such as superconducting cavity X radiation and radiation caused by material activation. This work is meaningful in BLM system research.