Author: Michel, P.
Paper Title Page
MOBL3 Electron Bunch Diagnostic at the Upgraded ELBE Accelerator: Status and Challenges 23
 
  • M. Kuntzsch, S. Findeisen, M. Gensch, B.W. Green, J. Hauser, S. Kovalev, U. Lehnert, P. Michel, F. Röser, Ch. Schneider, R. Schurig
    HZDR, Dresden, Germany
  • A. Al-Shemmary, M. Bousonville, M.K. Czwalinna, T. Golz, H. Schlarb, B. Schmidt, S. Schulz, N. Stojanovic, S. Vilcins
    DESY, Hamburg, Germany
  • E. Hass
    Uni HH, Hamburg, Germany
 
  Within the ELBE upgrade towards a Center for High Power Radiation Sources (HSQ), a mono energetic positron, a liquid lead photo neutron source and two new THz sources have been installed at the superconducting electron linac at ELBE. A variety of established as well as newly developed electron beam diagnostics were installed and tested. In this paper we want to present first results achieved with the currently existing prototype beam arrival time and bunch compression monitors (BAM, BCM) as well as one versatile EOS set-up. Based on these future developements and upgrades are discussed.  
slides icon Slides MOBL3 [3.578 MB]