Keyword: data-analysis
Paper Title Other Keywords Page
TUPA05 The Calibration Factor Determined and Analysis for HLS Bunch Current Measurement System pick-up, storage-ring, experiment, electron 334
 
  • Y.L. Yang, C. Cheng, P. Lu, T.J. Ma, B.G. Sun, J.G. Wang, J.Y. Zou
    USTC/NSRL, Hefei, Anhui, People's Republic of China
 
  Funding: Work supported by National Natural Science Project(11105141) and Chinese Universities Scientific Fund
For bunch current measurement, the calibration factor is a key parameter. Usually, button electrode or stripline electrode can be selected as signal pickup, and peak value or integral of bunch signal from pickup can be used to calculate the related bunch current value. To obtain the absolute value of bunch current, the calibration factor should be determined with the help of DCCT. At HLS, the Stretch effect of bunch length was observed when bunch current decay over time and this will affect the performance of bunch current detection for different pickup type and calculate method. Theoretical analysis and experimental validation results are performed to find out an ideal solution for bunch current measurement at HLS. The results show that, bunch current measurement system can obtain the best performance by stripline and its integral signal.