MOP233 |
Error and Tolerance Studies for Injector II of C-ADS |
125 |
|
- W.S. Wang, Y. He, Z.J. Wang
IMP, Lanzhou, People's Republic of China
|
|
|
The proposed Chinese Accelerator Driven System (C-ADS) driver linac is being designed by Chinese Academic Science (CAS). Injector II is designed and fabricated in Institute of Modern Physics (IMP). Injector II will accelerate 10 mA proton beams to 10 MeV. Because of the high final beam power (100 kW) specified for the linac operation, beam loss must be limited to 10-5 level to avoid radiation damage. Misalignment and RF error simulation for cavities and focusing elements after RFQ were performed and the correction schemes developed using the computing code TRACK. Error and tolerance studies for Injector II are presented.
|
|
|