THP061 | Commissioning of an Improved Superconducting RF Photo Injector at ELBE | 881 |
|
||
In order to produce high-brightness electron beams in a superconducting RF photo injector, the most important point is to reach a high acceleration field in the cavity. For this reason two new 3.5-cell niobium cavities were fabricated, chemically treated and cleaned in collaboration with Jlab. The first of these two cavities was shipped to HZDR and assembled in a new cryomodule. This new gun (SRF Gun II) was installed in the ELBE accelerator hall in May 2014 and replaces the previous SRF Gun I. Beside the new cavity the ELBE SRF gun II differs from the previous gun by the integration of a superconducting solenoid. The paper presents the results of the first test run with a Cu photocathode. | ||