Author: Wang, J.W.
Paper Title Page
TUOBNO04
Femtosecond Electron and X-ray Beam Temporal Diagnostics Using an X-band Transverse Deflector at LCLS  
 
  • Y. Ding, C. Behrens, J.C. Frisch, Z. Huang, P. Krejcik, H. Loos, T.J. Maxwell, J.W. Wang, M.-H. Wang, J.J. Welch
    SLAC, Menlo Park, California, USA
  • C. Behrens
    DESY, Hamburg, Germany
 
  X-ray free-electron lasers provide ultrashort x-ray pulses for multidisciplinary users. Temporal characterization of these ultrashort pulses with a femtosecond precision remains a challenging topic. At the Linac Coherent Light Source (LCLS), an X-band radio-frequency transverse deflector proposed in 2011 [*] has just been installed and commissioning of the RF system has started. By measuring the electron beam longitudinal phase space between lasing and non-lasing conditions, both the e-beam and x-ray temporal profiles can be reconstructed. We report the latest progress of the commissioning of the deflector and the measurements on the e-beam and x-ray pulse length with this deflector at LCLS. The resolution, stability and operational performance will also be discussed.
[*] Y. Ding et al., Phys. Rev. ST Accel. Beams 14, 120701 (2011)
 
slides icon Slides TUOBNO04 [4.086 MB]