Author: Turner, J.L.
Paper Title Page
WEPSO09 Two-Color Self-seeding and Scanning the Energy of Seeded Beams at LCLS 514
 
  • F.-J. Decker, Y. Ding, Y. Feng, M. Gibbs, J.B. Hastings, Z. Huang, H. Lemke, A.A. Lutman, A. Marinelli, A. Robert, J.L. Turner, J.J. Welch, D.H. Zhang, D. Zhu
    SLAC, Menlo Park, California, USA
 
  Funding: Work supported by U.S. Department of Energy, Contract DE-AC02-76SF00515.
The Linac Coherent Light Source (LCLS) produces typically SASE FEL pulses with an intensity of up to 5 mJ and at high photon energy a spread of 0.2% (FWHM). Self seeding with a diamond crystal reduces the energy spread by a factor of 10 to 40. The range depends on which Bragg reflection is used, or the special setup of the electron beam like over-compression. The peak intensity level is lower by a factor of about five, giving the seeded beam an advantage of about 2.5 in average intensity over the use of a monochromator with SASE. Some experiments want to scan the photon energy, which requires that the crystal angle be carefully tracked. At certain energies and crystal angles different lines are crossing which allows seeding at two or even three different colors inside the bandwidth of the SASE pulse. Out-off plane lines come in pairs, like [1 -1 1] and [-1 1 1], which can be split by using the yaw angle adjustments of the crystal, allowing a two-color seeding for all energies above 4.83 keV.
 
 
WEPSO10 Increased Stability Requirements for Seeded Beams at LCLS 518
 
  • F.-J. Decker, W.S. Colocho, Z. Huang, R.H. Iverson, A. Krasnykh, A.A. Lutman, M.N. Nguyen, T.O. Raubenheimer, M.C. Ross, J.L. Turner, L. Wang
    SLAC, Menlo Park, California, USA
 
  Funding: Work supported by U.S. Department of Energy, Contract DE-AC02-76SF00515.
Running the Linac Coherent Light Source (LCLS) with self-seeded photon beams requires better electron beam stability, especially in energy, to reduce the otherwise huge intensity variations of more than 100%. Code was written to identify and quantify the different jitter sources. Some improvements are being addressed, especially the stability of the modulator high voltage of some critical RF stations. Special setups like running the beam off crest in the last part of the linac can also be used to reduce the energy jitter. Even a slight dependence on the transverse position was observed. The intensity jitter distribution of a seeded beam is still more contained with peaks up too twice the average intensity, compared to the jitter distribution of a SASE beam going through a monochromator, which can have damaging spikes up to 5 times the average intensity.
 
 
WEPSO27 Recent LCLS Performance From 250 to 500 eV 554
 
  • R.H. Iverson, J. Arthur, U. Bergmann, C. Bostedt, J.D. Bozek, A. Brachmann, W.S. Colocho, F.-J. Decker, Y. Ding, Y. Feng, J.C. Frisch, J.N. Galayda, T. Galetto, Z. Huang, E.M. Kraft, J. Krzywinski, J.C. Liu, H. Loos, X.S. Mao, S.P. Moeller, H.-D. Nuhn, A.A. Prinz, D.F. Ratner, T.O. Raubenheimer, S.H. Rokni, W.F. Schlotter, P.M. Schuh, T.J. Smith, M. Stanek, P. Stefan, M.K. Sullivan, J.L. Turner, J.J. Turner, J.J. Welch, J. Wu, F. Zhou
    SLAC, Menlo Park, California, USA
  • P. Emma
    LBNL, Berkeley, California, USA
  • R. Soufli
    LLNL, Livermore, California, USA
 
  Funding: Work supported by US Department of Energy contract DE-AC02-76SF00515 and BES.
The Linac Coherent Light Source is an X-ray free-electron laser at the SLAC National Accelerator Laboratory. It produces coherent soft and hard X-rays with peak brightness nearly ten orders of magnitude beyond conventional synchrotron sources and a range of pulse durations from 500 to <10 fs. The facility has been operating at X-ray energy from 500 to 10,000eV. Users have expressed great interest in doing experiments with X-Rays near the carbon absorption edge at 284eV. We describe the operation and performance of the LCLS in the newly established regime between 250 and 500eV.
[1] Emma, P. et al., “First lasing and operation of an ˚angstrom-wavelength free-electron laser,” Nature Pho-
ton. 4(9), 641–647 (2010).