Author: Corbett, W.J.
Paper Title Page
TUPSO84 SLAC RF Gun Photocathode Test Facility 427
 
  • T. Vecchione, A. Brachmann, W.J. Corbett, M.J. Ferreira, S. Gilevich, E.N. Jongewaard, H. Loos, J. Sheppard, S.P. Weathersby, F. Zhou
    SLAC, Menlo Park, California, USA
 
  Funding: Work supported by US DOE contract DE-AC02-76SF00515.
A RF gun photocathode test facility has been commissioned at SLAC. The facility consists of a S-band gun, high power RF, a UV drive laser and beam diagnostics. Here we report on the capabilities of the facility demonstrated during commissioning. Currently the facility is being used to study in-situ laser processing of copper photocathodes. In the future the facility will be used to study fundamental gun and photocathode performance limitations and enhancement strategies. Eventually it is envisioned to integrate a load lock and plug into the gun enabling the evaluation of high performance surface sensitive semiconductor photocathodes and the incorporation of ex-situ surface science analytical techniques.