Author: Douglas, D.
Paper Title Page
THPD65 High Dynamic Range Beam Imaging with Two Simultaneously Sampling CCDs 670
 
  • P. Evtushenko, D. Douglas, R.A. Legg, C. Tennant
    JLAB, Newport News, Virginia, USA
 
  Transverse beam profile measurement with sufficiently high dynamic range (HDR) is a key diagnostic to measure the beam halo, understand its sources and evolution. In this contribution we describe our initial experience with the HDR imaging of the electron beam at the JLab FEL. On contrary to HDR measurements made with wire scanners in counting mode, which provide only two or three 1D projections of transverse beam distribution, imaging allows to measure the distribution itself. That is especially important for non-equilibrium beams in the LINACs. The measurements were made by means of simultaneous imaging with two CCD sensors with different exposure time. Two images are combined then numerically in to one HDR image. The system works as an online tool providing HDR images at 4 Hz. An optically polished YAG:Ce crystal with the thickness of 100 um was used for the measurements. When tested with a laser beam images with the DR of about 10+5 were obtained. With the electron beam the DR was somewhat smaller due to the limitations in the time structure of the tune-up beam macro pulse.