Author: Peters, F.
Paper Title Page
WEPB04 Position Stability Monitoring of the LCLS Undulator Quadrupoles 398
 
  • H.-D. Nuhn, G.L. Gassner, F. Peters
    SLAC, Menlo Park, California, USA
 
  Funding: This work was supported by U.S. Department of Energy, Office of Basic Energy Sciences, under Contract DE-AC02-76SF00515
In the era of SASE FELs, the demand for position stability of undulator components scales down to the range of sub-micrometers per day. Simultaneously, the undulator length increases significantly, in order to reach X-ray wavelengths. To minimize the impact of the outside environment, the LCLS undulator is placed underground, but reliable data about ground motion inside such a tunnel were not available in the required stability range. Therefore, a new position monitor system has been developed and installed for the LCLS undulator. That system is capable to measure X-, Y- and Roll positions of each of the 33 undulator quadrupoles, with respect to stretched wires. Instrument resolution is about 20 nm and instrument drift is negligible small. Position data of individual quadrupoles can be correlated along the entire undulator, which has a length of 132 m. The system is under continuous operation since 2009. The report describes long term experience with the running system and the observed position stability of the undulator quadrupoles.