A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Trovo, M.     [Trovò, M.]

Paper Title Page
MOPA02 Recent Commissioning Experience on the FERMI@Elettra First Bunch Compressor Area: Investigations of Beam Dynamics, Modeling and Control Software 26
 
  • S. Di Mitri, E. Allaria, R. Appio, L. Badano, D. Castronovo, M. Cornacchia, P. Craievich, S. Ferry, L. Froehlich, S.V. Milton, G. Penco, C. Scafuri, C. Spezzani, M. Trovò, M. Veronese
    ELETTRA, Basovizza
  • R. Bartolini
    Diamond, Oxfordshire
  • G. De Ninno, S. Spampinati
    University of Nova Gorica, Nova Gorica
  • P. Evtushenko
    JLAB, Newport News, Virginia
  • W.M. Fawley
    LBNL, Berkeley, California
  • L. Giannessi
    ENEA C.R. Frascati, Frascati (Roma)
  • A.A. Lutman
    DEEI, Trieste
  • M. Sjöström
    MAX-lab, Lund
 
 

Some experiences have recently been collected from the FERMI@elettra Free Electron Laser first bunch compressor area. This includes a magnetic compressor, diagnostics for the characterization of the longitudinal and transverse phase space and suitable optics for matching to the downstream part of the linac. We report on the beam dynamics investigations in comparison with the modeling as well as the high level software control that has allowed this experience.

 
TUOAI2 The Elettra Storage-Ring Free-Electron Laser: a Source for FEL Studies and User Experiments 188
 
  • G. De Ninno, E. Allaria, M.B. Danailov, E. Karantzoulis, C. Spezzani, M. Trovò
    ELETTRA, Basovizza
  • M. Coreno
    CNR - IMIP, Trieste
  • G. De Ninno
    University of Nova Gorica, Nova Gorica
  • E. Ferrari
    Università degli Studi di Trieste, Trieste
  • G. Geloni
    European XFEL GmbH, Hamburg
 
 

The paper will report about the last achievements of the Elettra storage-ring FEL. The latter include: a) a noticeable improvement of the source performance (generation of coherent radiation at 87 nm, attainment of a very good shot-to-shot stability); b) general FEL studies, relevant to single-pass devices (characterization of the angular distribution of harmonic emission, analysis of the frequency pulling effect), and c) first user experiments (pump-probe on gas phase and solid-state samples).

 

slides icon

Slides