WEPB06 Measurement and Simulation Studies of Emittance for Short Gaussian Pulses at PITZ 402
 
  • M.A. Khojoyan, G. Asova, J.W. Bähr, H.-J. Grabosch, L. Hakobyan, M. Hänel, Ye. Ivanisenko, M. Krasilnikov, M. Mahgoub, M. Otevrel, B. Petrosyan, S. Rimjaem, A. Shapovalov, R. Spesyvtsev, L. Staykov, F. Stephan, G. Vashchenko
    DESY Zeuthen, Zeuthen
  • G. Klemz
    MBI, Berlin
  • S. Lederer
    DESY, Hamburg
  • B.D. O'Shea
    UCLA, Los Angeles, California
  • D. Richter
    HZB, Berlin
  • J. Rönsch-Schulenburg
    Uni HH, Hamburg
 
 

The Photo Injector Test facility at DESY, Zeuthen site (PITZ), develops and optimizes electron sources for Free Electron Lasers (FEL’s) such as FLASH and European XFEL. The electrons are generated by the photo effect using a cesium telluride (Cs2Te) cathode and are accelerated in an 1.6-cell L-band RF-gun cavity with about 60MV/m maximum accelerating field at the cathode. The upgraded laser system at PITZ produces flat-top and Gaussian laser pulses of different time durations. Emittance measurements have been done for short Gaussian laser temporal profile ~2ps FWHM and for 6.6 MeV electron beam energy. The transverse projected emittance was measured for various transverse laser spot sizes at the cathode and different low bunch charges to find an optimum condition for thermal emittance measurements. ASTRA simulations were performed for various measurement conditions to estimate the space charge contribution to the emittance. The comparison of emittance measurement results and simulations is presented and discussed in this contribution.

 
WEPB09 Measurements and Simulations of Emittance for Different Bunch Charges at PITZ 410
 
  • S. Rimjaem, G. Asova, J.W. Bähr, H.-J. Grabosch, L. Hakobyan, M. Hänel, Ye. Ivanisenko, M.A. Khojoyan, G. Klemz, M. Krasilnikov, M. Mahgoub, M. Otevrel, B. Petrosyan, A. Shapovalov, R. Spesyvtsev, L. Staykov, F. Stephan
    DESY Zeuthen, Zeuthen
  • S. Lederer
    DESY, Hamburg
  • M.A. Nozdrin
    JINR, Dubna, Moscow Region
  • B.D. O'Shea
    UCLA, Los Angeles, California
  • D. Richter
    HZB, Berlin
  • J. Rönsch-Schulenburg
    Uni HH, Hamburg
 
 

Transverse projected emittance optimization is one of the main research activities at the Photo Injector Test facility at DESY, Zeuthen site (PITZ). The emittance measurement program in the 2009 run period concentrated on projected emittance measurements using a single sit scan technique. The photocathode laser profile has been optimized yielding small emittance. The flat-top temporal profile has been used in the standard projected emittance measurements. The small emittance values down to less than 1 mm-mrad have been measured for the nominal 1 nC bunch charge. Emittance optimizations for lower bunch charges have also been conducted using the same measurement setup and procedure as for the case of 1 nC. Numerical simulations have been carried out to compare the results with the measurements. Measurement and simulation results of the transverse emittance for the bunch charges of 0.1, 0.25, 0.5 and 1 nC will be reported and discussed in this contribution.

 
WEOC4 Phase Space Measurements with Tomographic Reconstruction at PITZ 529
 
  • G. Asova, J.W. Bähr, H.-J. Grabosch, L. Hakobyan, M. Hänel, Ye. Ivanisenko, M.A. Khojoyan, G. Klemz, M. Krasilnikov, M. Mahgoub, M. Otevrel, B. Petrosyan, S. Rimjaem, A. Shapovalov, L. Staykov, F. Stephan, G. Vashchenko
    DESY Zeuthen, Zeuthen
  • S. Lederer
    DESY, Hamburg
  • B.D. O'Shea
    UCLA, Los Angeles, California
  • D. Richter
    HZB, Berlin
 
 

The major objectives of the Photo-Injector Test Facility at DESY in Zeuthen, PITZ, are research and development of high brightness electron sources suitable to drive FELs like FLASH and the European XFEL. In the 2008/2009 run period the facility has been operated with a new photo-cathode laser system and a dry-ice cleaned RF gun cavity. Characterization of the transverse phase space of the electron source has been performed in details using a single slit scan technique with a dedicated Emittance Measurement System. In preparation for the forthcoming run, a number of quadrupole magnets have been installed and tomography reconstruction with data from quadrupole scans with two magnets has been carried out in semi-parallel manner to the slit scans. This contribution summarizes the experience from the phase-space tomography reconstruction with nominal beam conditions. Advantages and drawbacks of the measurement procedure and the analysis are superimposed and results are compared to ones obtained with the slit scans.

 