Paper | Title | Page |
---|---|---|
WEPB05 | Conditioning of a New Gun at PITZ Equipped with an Upgraded RF Measurement System | 398 |
|
||
A new photocathode electron gun is about to be characterized at PITZ*. It is an L-band normal conducting 1.6 copper cell cavity with improved cooling system. It has the same design as the previously installed gun, characterized at PITZ during the run period 2008/9**. Due to the particle-free surface cleaning method utilizing dry ice, a significant reduction of the dark current was achieved in case of the previously tested cavity. This effect is also expected for the new gun. To improve the accuracy of the RF power measurement and control, a new in-vacuum directional coupler was installed between the T-combiner combining the two 5 MW arms of the RF source and the input coaxial coupler. The new in-vacuum coupler will provide much more accurate information about the RF power in the gun and will allow applying appropriate control feedback. Consequently improved stability of the gun operation is expected. Tuning and conditioning results of this new gun cavity will be presented as well as the results of the measurements of the gradient and the gun phase measurements using this new coupler. * Photoinjector Test Facility at Zeuthen |
||
WEPB10 | Low-charge Simulations for Phase Space Tomography Diagnostics at the PITZ Facility | 414 |
|
||
The Photo-Injector Test Facility at DESY, Zeuthen site (PITZ) aims to optimize high brightness electron sources for linac-based FELs. Since the performance of an FEL strongly depends on the transverse electron beam emittance, the electron source is studied in details at PITZ by measuring the emittance with the help of the Emittance Measurement Systems (EMSYs). The EMSY employs the slit scan technique which is optimized for 1nC bunch charge and, therefore, it might not be an optimal choice for low charge bunches. To extend the ability of the facility for transverse phase space measurements, a module for phase-space tomography diagnostics and its matching section are installed in 2010. The basic components of the module are four screens separated by FODO cells. It is designed for operation with high charge and low energy beams*. This work studies the performance of the tomography module when it is operated with low charge beams. The influence of different beam parameters is evaluated according to the requirement to match the envelope to the optics of the FODO lattice. Simulation results and phase space reconstructions are presented. G. Asova et al., ‘Design considerations for phase space tomography diagnostics at the PITZ facility', proceedings of DIPAC 2007, Mestre, Italy. |
||
WEPB10 | Low-charge Simulations for Phase Space Tomography Diagnostics at the PITZ Facility | 414 |
|
||
The Photo-Injector Test Facility at DESY, Zeuthen site (PITZ) aims to optimize high brightness electron sources for linac-based FELs. Since the performance of an FEL strongly depends on the transverse electron beam emittance, the electron source is studied in details at PITZ by measuring the emittance with the help of the Emittance Measurement Systems (EMSYs). The EMSY employs the slit scan technique which is optimized for 1nC bunch charge and, therefore, it might not be an optimal choice for low charge bunches. To extend the ability of the facility for transverse phase space measurements, a module for phase-space tomography diagnostics and its matching section are installed in 2010. The basic components of the module are four screens separated by FODO cells. It is designed for operation with high charge and low energy beams*. This work studies the performance of the tomography module when it is operated with low charge beams. The influence of different beam parameters is evaluated according to the requirement to match the envelope to the optics of the FODO lattice. Simulation results and phase space reconstructions are presented. G. Asova et al., ‘Design considerations for phase space tomography diagnostics at the PITZ facility', proceedings of DIPAC 2007, Mestre, Italy. |