A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Keil, B.

Paper Title Page
WEPB15 Commissioning of The Low-Charge Resonant Stripline BPM System For The SwissFEL Test Injector 429
 
  • B. Keil, A. Citterio, M.M. Dehler, R. Ditter, V. Schlott, L. Schulz, D.M. Treyer
    PSI, Villigen
 
 

This paper introduces the architecture and first beam commissioning results of the standard BPM system for the SwissFEL test injector, a 250MeV linac that is progressively being commissioned in order to perform R&D for the "SwissFEL" 5.8GeV hard-X-ray FEL facility proposed at PSI. Since the SwissFEL has a nominal bunch charge range of 10-200pC, the test injector is equipped with 500MHz resonant stripline BPMs that are optimized for high dynamic range and sensitivity, to support machine operation well below 10pC. Beam tests with a 5 GSa/s direct sampling electronics designed at PSI showed a single-bunch resolution of <20um RMS at 2pC and typically 7um RMS for charges >10pC. The BPMs also measure bunch charge, insensitively to dark current, with <30fC RMS resolution at 2pC.

 
THPA08 Study of Beam Based Alignment and Orbit Feedback for SwissFEL 588
 
  • M. Aiba, H.-H. Braun, M. Böge, C. Calvi, T. Garvey, B. Keil, S. Reiche, V. Schlott, T. Schmidt
    PSI, Villigen
 
 

Transverse beam trajectory control is of great importance for SwissFEL as the lasing strategy is based on a relatively low energy and low emittance beam compared with other X-FEL facilities, thus aiming at a reasonable construction cost and size of the facility. A study of beam based alignment and orbit feedback has been performed, and a trajectory correction scenario, which would fulfill the beam requirements as well as the hardware constraints, has been set up. The beam based alignment will be discussed for the linac and the undulator section separately because of the much tighter tolerance in the latter. Several correction algorithms are examined using numerical simulations. BPM requirements and orbit feedback concept will be discussed, with reference to some available data on dynamic disturbances such as ground motion at the PSI site, e.g. at the SwissFEL injector test facility currently under commissioning.