A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Danared, H.

Paper Title Page
THPC12 XFEL Activities at MSL: Undulator Temperature Compensation and Quadrupole Fiducialization 675
 
  • A. Hedqvist, H. Danared, F. Hellberg
    MSL, Stockholm
  • W. Decking, B. Krause
    DESY, Hamburg
  • S. Karabekyan, J. Pflüger
    European XFEL GmbH, Hamburg
 
 

The Manne Siegbahn Laboratory at Stockholm University is currently involved in two separate projects at the European XFEL. The first concerns the fiducialization and characterization of the quadrupole magnets in the undulator sections. A recently upgraded rotating coil system measures the magnetic centre stability during magnet excitation, magnet gradient and field error components. In connection, a coordinate measuring machine is used to fiducialize the quadrupole magnetic centre to better than 0.050 mm. The second project concerns high precision measurements of the undulator temperature. The SASE radiation intensity depends strongly on the undulator period and the magnetic field strength, which are both sensitive to temperature. Instead of keeping the temperature within 0.1 degrees along the undulator tunnel, a temperature compensation scheme can be applied. Here, a change in temperature initiates adjustment of the undulator gap to compensate for changes in magnetic field. A system for undulator segment temperature measurement, with resolution of 0.03 degrees, necessary for the compensation scheme, is presented together with a brief overview of the upgraded rotating coil system.