Paper | Title | Page |
---|---|---|
THOC4 | Improvement in High-Frequency Properties of Beam Halo Monitor Using Dimond Detectors for SPring-8 XFEL | 700 |
|
||
An interlock sensor is indispensable to protect the undulator magnets against radiation damage. The beam halo monitor using diamond detectors, which are operated in photoconductive mode, has been developed for the X-ray free electron laser facility at SPring-8 (XFEL/SPring-8). Pulse-by-pulse measurements are adopted to suppress the background noise efficiently, and to improve the detective sensitivity. The feasibility tests of this monitor have been demonstrated at the SPring-8 compact SASE source (SCSS) test accelerator for SPring-8 XFEL. As the next step, we are trying to improve the high-frequency properties: (a) dimension of diamond detectors was newly designed to optimize the beam halo monitor for SPring-8 XFEL, (b) the microstripline structure is applied in the vacuum chamber to improve the high-frequency property, (c) RF fingers are also applied to suppress the effect of the wake field from intense electron beam. Details of these devices and experimental results are presented. |
||
|