A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Kang, B.-K.

Paper Title Page
TUPPH084 Field Mapping System for KIRAMS-30 Cyclotron Magnet 442
 
  • K.-H. Park, D. E. Kim, Y. G. Young-Gyu, Y. D. Yun
    PAL, Pohang, Kyungbuk
  • J.-S. Chai, J. Kang
    KIRAMS, Seoul
  • B.-K. Kang
    POSTECH, Pohang, Kyungbuk
 
  This paper presents a Hall probe mapping system for measuring a cyclotron magnet, which has been fabricated for the 30 MeV cyclotron at the Korea Institute of Radiological and Medical Sciences. The Hall probes are mounted on a precision mechanical stage and map magnetic field in the Cylindrical coordinate system. The mapping system uses the “flying” mode field mapping method to reduce data-acquisition time. The time required for mapping the whole gap-area of the cyclotron magnet is ~70 minutes. The relative random fluctuation error during the entire mapping process is less than ±0.02%. The cyclotron magnet has been corrected using field measurement data, and the achieved total phase excursion of the cyclotron after correction is less than ±15°, which is within the tolerance of ±20° for the total phase excursion.