Author: Kobayashi, M.
Paper Title Page
TUIBLH1021
Development of a 500 kV DC Gun with Narrow Gap  
 
  • M. Yamamoto, Y. Honda, X.J. Jin, M. Kobayashi, T. Miyajima, T. Uchiyama
    KEK, Ibaraki, Japan
  • R. Hajima, R. Nagai, N. Nishimori
    JAEA, Ibaraki-ken, Japan
  • M. Kuriki
    Hiroshima University, Graduate School of Science, Higashi-Hiroshima, Japan
  • H. Kurisu
    Yamaguchi University, Ube-Shi, Japan
 
  The second 500 kV DC gun with 70 mm anode-cathode gap has been constructed at KEK. In 2014, a high voltage conditioning up to 550 kV was carried out and a 500 kV test has been done more than 50 hours intermittently without any trips. The vacuum of the gun is achieved 6x10-10 Pa during a 500 kV test by pumping NEGs and a bakable cryopump. A beam test has been started from the end of March 2015.  
slides icon Slides TUIBLH1021 [2.466 MB]  