Author: Higurashi, Y.
Paper Title Page
MOOBMH02 Emittance Measurements For RIKEN 28 GHz SC-ECRIS 10
 
  • Y. Higurashi, T. Nakagawa, J. Ohnishi, K. Ozeki
    RIKEN Nishina Center, Wako, Japan
 
  In 2013, the intense beams of highly charged uranium ion (180euA of U35+, 230euA of U33+) were extracted from RIKEN SC-ECRIS. Following the success, intense beam of U35+ ions was used for the RIBF experiment for 24 days without break. It is obvious that production of high-quality beam (smaller emittacne and good stability etc) is also important for RIKEN radio isotope beam factory (RIBF) project. For this reason, in 2014, we systematically measured the emittance and beam intensity of the highly charged uranium ions under various conditions (magnetic field configuration, extracted beam intensity, beam stability etc) to search the optimum condition. In these experiments, we observed that the emittnce size is strongly dependent on the magnetic field configuration, especially Bext. In this contribution, we present the effect of the various parameters (magnetic field configuration, extracted beam intensity, beam stability etc) of the SC-ECRIS on the beam intensity and emittance. We also discuss its mechanism in detail.  
slides icon Slides MOOBMH02 [2.472 MB]