Author: Yin, Y.
Paper Title Page
MOPCP106 Beam-Phase Measurement System for HIRFL 263
 
  • J.H. Zheng, W. Liu, W. Ma, R.S. Mao, Y. Wang, J.X. Wu, Y. Yin
    IMP, Lanzhou, People's Republic of China
 
  The beam phase measurement system in HIRFL is introduced. The system had been improved using RF-signal mixing and filtering techniques and noise cancellation method. Therefore,the influence of strongly RF field disturbing signal was eliminated and the signal to noise rate was increased, and a stable and sensitive phase measurement system was developed. The phase history of the ion beam was detected by using 15 set of capacitive pick-up probes installed in the SSC cyclotron. The phase information of the measurement was necessary for tuning purposes to obtain an optimized isochronous magnetic field, where the beam intensity was increased and the beam quality was optimized . The measuremnet results before and after isochronous magnetic field for ion and ion in SSC was given . The phase measurement system was reliable by optimizing isochronous magnetic field test,and the precision reached ±0.5°,the sensitivity of the beam signal measurement was about 10nA as well.