Author: Ma, L.Z.
Paper Title Page
MOA2CIO01 HIRFL-CSR Facility Status and Development 37
 
  • Y.J. Yuan, X.H. Cai, D.Q. Gao, Y. He, L.Z. Ma, X. Ma, R.S. Mao, Y.W. Su, X.L. Tu, J.W. Xia, H.S. Xu, Z. Xu, J.C. Yang, X.D. Yang, X.T. Yang, Y.P. Yang, W. Zhang, H.W. Zhao
    IMP, Lanzhou, People's Republic of China
 
  The HIRFL-CSR facility come into operation by the end of 2007. During operation in recent years, CSR supplied beam for experiments at several terminals and inside both CSRm and CSRe rings. The experiments covers high resolution mass measurement, cancer therapy research, neutron wall, atomic physics using electron target and internal gas target, using injection beam mainly from the SFC of cyclotron injector. New methods and further developments are required to improve the performance of CSR system including multi-gradients measurement method for beam spot commissioning and beam transfer, nonlinear effect correction and stabilization of isochronous mode of CSRe. For suppling of heverier ion beam with proper ernergy, the cyclotron complex should be enhanced and new injector is proposed to replace SFC as injector of SSC.  
slides icon Slides MOA2CIO01 [3.766 MB]  
 
MOPCP002 The Isochronous Magnetic Field Optimization of HITFiL Cyclotron 48
 
  • L.Z. Ma, Q.G. Yao
    IMP, Lanzhou, People's Republic of China
 
  A new project named HITFiL (Heavy Ion Therapy Facility in Lanzhou) is being constructed. In this project, a 7 Mev 12C5+ cyclotron is selected as the initial injector providing a 10 μA carbon beam. The isochronous magnetic field optimization of the cyclotron is introduced in this paper. Optimization result shows that the deviations between calculation values and theory are smaller than 5 Gs. In the design process, the sofware OPERA has been utilized for the field calculation and optimization.  
 
MOPCP100 Axial Injection Beam Line of a Compact Cyclotron 254
 
  • J.Q. Zhang, Y. Cao, L.Z. Ma, A. Shi, M.T. Song, L.P. Sun, X.T. Yang, Q.G. Yao, Z.M. You, X.Q. Zhang, X.Z. Zhang, H.W. Zhao, J.H. Zheng
    IMP, Lanzhou, People's Republic of China
 
  Axial injection beam line of the therapy cyclotron is presented. It is intended for transportation of the C5+ ion beam obtained in the permanent magnet ion source. The beam line is only 3.486 m from the ion source to the entrance of spiral inflector, it consists of two sets glasser lens, one set double 90° bend magnet, one quadrupole lens and two solenoid lens. A big vacuum chamber is installed in the vertical part of the beam line, the sinusoidal buncher, the Faraday cap, the slit collimator and chopper are located in the vacuum chamber. The sinusoidal buncher is used for increasing of the seizing efficiency. The Faraday cap is used for the beam diagnostics. The bend magnet with the slit collimator is used for choice of C5+ ion beam. The chopper is used for choice of the beam utilizing time.  
 
TUA2CCO03 Design and Construction Progress of a 7 MeV/u Cyclotron 317
 
  • B. Wang, D.Q. Gao, H.F. Hao, L.Z. Ma, K.D. Man, M.T. Song, X.W. Wang, X.T. Yang, Q.G. Yao, Z.M. You, J.Q. Zhang, S.H. Zhang, X.Q. Zhang, H.W. Zhao
    IMP, Lanzhou, People's Republic of China
 
  The 7MeV/u cyclotron accelerates carbon ions with mass number 12, 5+ charges, the extraction energy of carbon ions is 7 MeV/u, and the beam current density is designed to be 10 eμA. It designed as injector for the HITFiL (Heavy Ions Therapy Facility in LanZhou) synchrotron, which accelerates carbon ions to the energy 300 MeV/u for tumors treatment. Computer modeling results on the axial injection, magnetic, accelerating and extraction systems of the cyclotron are given. Design of the main systems of the cyclotron and the results of beam dynamic simulations are introduced. The construction progress including the ECR ion source, the axial injection beam line, the magnet, the RF system, the vacuum system etc. will be described respectively.  
slides icon Slides TUA2CCO03 [1.679 MB]