Author: Hu, W.P.
Paper Title Page
MOPCP026 Beam Extraction System for CYCIAE-14 105
 
  • S.M. Wei, S. An, W.P. Hu, M. Li, Y.L. Lu, L.P. Wen, H.D. Xie, J.S. Xing, Z.G. Yin, T.J. Zhang
    CIAE, Beijing, People's Republic of China
 
  A 14MeV medical cyclotron is under design and construction at CIAE, and H ion will be accelerated and extracted by carbon stripper in dual opposite direction. Two stripping points are chosen in each extracting direction to extract proton beams to different targets or beam lines to extend the use of the machine. Two modes have been considered for the extraction system. One is designed to be installed on the wall of the vacuum cavity, and the other is designed to be inserted vertically from the sector poles. The final choice depends on the agility, simplicity and results of the experimentation. The angle between the stripper and the beam orbit is optimized to improve the extracted beam quality. The results of numerical simulation show the two stripping points at each extraction direction, the beam orbit and the beam characteristic at each extraction direction. The comparison of the beam envelope of different stripper azimuth is also presented in this paper to show the influence of the stripper azimuth. Based on the concept design, the mechanical design and the experimentation of the DC motor in magnetic field have been conducted, with the results shown in the paper as well.