Author: Dey, M.K.
Paper Title Page
MOPCP041 Beam Tuning in Kolkata Superconducting Cyclotron 132
 
  • M.K. Dey, R.K. Bhandari, U. Bhunia, J. Debnath, A. Dutta, C. Mallik, Z.A. Naser, S. Paul, J. Pradhan, M.H. Rashid
    DAE/VECC, Calcutta, India
 
  The Superconducting cyclotron at VECC, Kolkata, has accelerated ion beams up to extraction radius successfully confirmed by the neutrons produced by the nuclear reactions. The internal beam tuning process started with beam parameters calculated using the measured magnetic field data. Due to some mechanical and electrical problems we were forced to tune the beam with three major trim coils off. Accurate positioning of central region Dee-extensions ensuring the proper acceleration gaps in the first turn was required for successful acceleration of beam through the compact central region clearing the posts in the median plane. Here we present different aspects and results of initial beam tuning.  
 
MOPCP059 Theoritical Analysis and Fabrication of Coupling Capacitor for K500 Superconducting Cyclotron at Kolkata 165
 
  • M. Ahammed, R.K. Bhandari, P. Bhattacharyya, J. Chaudhuri, M.K. Dey, A. Dutta Gupta, B. Hemram, B.C. Mandal, N. Mandal, B. Manna, S. Murali, Y.E. Rao, S. Saha, S. Sur
    DAE/VECC, Calcutta, India
 
  K500 SC cyclotron has already been constructed and commissioned after spiraling Ne3+ internal beam with 70 nA upto extraction radius(670 mm) at Variable Energy Cyclotron Centre at Kolkata, India. Several problems have been experienced related to the coupling capacitor of the radio frequency system including it's sever burning during commissioning of the cyclotron. Making of the dissimilar joints between alumina ceramic and copper of the coupling capacitor demands the usage of vacuum furnace to avoid the cracking of the ceramic. Therefore exhaustive analysis has been carried out to facilitate the in-house fabrication of the coupling capacitor without using the vacuum furnace in case of emergency. The maximum allowable rate of temperature rise for the ceramic and the optimum thickness ration of the copper to ceramic has been estimated. Finally fabrication of the coupling capacitor has been carried out in-house without employing vacuum furnace. At present the coupling capacitor is performing well as maximum 57 kV DEE voltages were been achieved the till date. This paper presents the details of the analysis and experiences gain during the fabrication of the coupling capacitor.  
 
MOPCP076 Operational Experience of Superconducting Cyclotron Magnet at VECC, Kolkata 203
 
  • U. Bhunia, M. Ahmed, R.K. Bhandari, T. Bhattacharyya, M.K. Dey, R. Dey, A. Dutta, A. Dutta Gupta, C. Mallik, C. Nandi, Z.A. Naser, G.P. Pal, U. Panda, S. Paul, J. Pradhan, S. Saha
    DAE/VECC, Calcutta, India
 
  The Kolkata Superconducting cyclotron magnet has been operational in the center since last few years and enabled us to extensively map magnetic fields over a year covering the operating range of the machine and successful commissioning of internal beam. The magnet cryostat coupled with the liquid helium refrigerator performs satisfactorily with moderate currents (<550A) in both the coils. The superconducting coil did not undergo any training and over the years has not suffered from any quench. Author would share the experience and difficulties of enhanced overall heat load to the liquid helium refrigerator at higher excitations of coils. This creates instability in the operation of liquid helium refrigerator and finally leads to slow dump. Rigorous study has been carried out in this regard to understand the problems and operational logic of liquid helium refrigerator has been modified accordingly to alleviate from. Some other measures have also been taken from cryostat and cryogenic distribution point of view in order to reduce the heat load at higher excitations.  
 
MOPCP078 Study of Magnetic Field Imperfections of Kolkata Superconducting Cyclotron 209
 
  • J. Pradhan, R.K. Bhandari, U. Bhunia, J. Debnath, M.K. Dey, C. Mallik, S. Paul
    DAE/VECC, Calcutta, India
 
  Analysis of the magnetic data obtained during the magnetic field mapping of Kolkata superconducting cyclotron showed imperfections in the main magnetic field. Since the main magnet of the superconducting cyclotron is three fold rotationally symmetric, any deviation from this symmetry creates imperfections in the magnetic field. Generally, 1st and 2nd harmonic components are inherently present in the field due to assembling errors in iron/coil. A major portion of these imperfections is attributed to the misplacement/tilting of the iron pole tip with respect to coil. The error in positioning of main superconducting coil with respect to surrounding iron produces another imperfection. Pole tip deformation due to rise of temperature produces field imperfection. This paper reports the various possible sources of imperfection in general and their estimation. The calculation was compared with measured data to find out the actual cause of imperfections and necessary corrections  
 
MOPCP093 Beam Extraction System and External Beam Line of Kolkata Superconducting Cyclotron 242
 
  • J. Debnath, S. Bhattacharya, T. Bhattacharyya, U. Bhunia, P.S. Chakraborty, M.K. Dey, C. Mallik, Z.A. Naser, G.P. Pal, S. Paul, J. Pradhan
    DAE/VECC, Calcutta, India
 
  All the major components of the extraction system of the Kolkata superconducting cyclotron are installed and functional. It includes the Electrostatic deflectors, magnetic channels, M9 slit etc. Internal beam acceleration has already been done successfully and now we are on the verge of extracting and transporting the beam to the cave. The external beam transport system has been designed comprising of quadrupole magnets, steering magnets, switching magnets, beam diagnostics etc. One of the four beam lines has been installed, which extends 20 meters up to the experimental cave - 1. Control and monitoring system for all these components have been developed and tested. All the beam dynamical and technical aspects of the beam extraction and beam transportation have been discussed in this paper.