Author: Bhattacharyya, P.
Paper Title Page
MOPCP059 Theoritical Analysis and Fabrication of Coupling Capacitor for K500 Superconducting Cyclotron at Kolkata 165
 
  • M. Ahammed, R.K. Bhandari, P. Bhattacharyya, J. Chaudhuri, M.K. Dey, A. Dutta Gupta, B. Hemram, B.C. Mandal, N. Mandal, B. Manna, S. Murali, Y.E. Rao, S. Saha, S. Sur
    DAE/VECC, Calcutta, India
 
  K500 SC cyclotron has already been constructed and commissioned after spiraling Ne3+ internal beam with 70 nA upto extraction radius(670 mm) at Variable Energy Cyclotron Centre at Kolkata, India. Several problems have been experienced related to the coupling capacitor of the radio frequency system including it's sever burning during commissioning of the cyclotron. Making of the dissimilar joints between alumina ceramic and copper of the coupling capacitor demands the usage of vacuum furnace to avoid the cracking of the ceramic. Therefore exhaustive analysis has been carried out to facilitate the in-house fabrication of the coupling capacitor without using the vacuum furnace in case of emergency. The maximum allowable rate of temperature rise for the ceramic and the optimum thickness ration of the copper to ceramic has been estimated. Finally fabrication of the coupling capacitor has been carried out in-house without employing vacuum furnace. At present the coupling capacitor is performing well as maximum 57 kV DEE voltages were been achieved the till date. This paper presents the details of the analysis and experiences gain during the fabrication of the coupling capacitor.  
 
MOPCP095 Experiment and Analysis: Partial Loss of Insulation Vacuum in K-500 Superconducting Cyclotron During Energization 248
 
  • P. Bhattacharyya, M. Ahammed, S. Bandyopadhyay, R.K. Bhandari, U. Bhunia, J. Chaudhuri, A. De, A. Dutta Gupta, C. Mallik, A. Mukherjee, C. Nandi, U. Panda, S. Saha, S. Saha
    DAE/VECC, Calcutta, India
 
  At higher currents in superconducting coil of K-500 Superconducting cyclotron, it was found that the insulation vacuum surrounding the LHe vessel gets worsen with increased current in the coil,finally leading to slow dump of power of the coil. This is a limitation for further increasing current value in the superconducting magnet coil. But once the current value returned to zero, vacuum reading reaches its initial value. Experiment & analysis have been done to quantify the contribution of molecular gas conduction on heat load because of this partial loss of insulation vacuum. Experiment was done to quantify how much betterment in terms of heat load is possible by incorporating additional vacuum pump. The cryostat safety analysis because of loss of insulation vacuum has become very important at this new scenario. Analysis has been done to know what could be the maximum pressure rise with time in case of loss of vacuum. This data has been used to know what should be the relieving mass flow rate to avoid any pressure burst accident. Finally this data has been compared with the existing relief valve. It is found that the existing safety system can take care of such incident.