TUPG022 Transverse Beam Profile Monitoring using Scintillation Screens for High Energy Ion Beams 183
 
  • K. Renuka, W. Ensinger
    TU Darmstadt, Darmstadt, Germany
  • C.A. Andre, F. Becker, P. Forck, R. Haseitl, A. Reiter, B. Walasek-Höhne
    GSI, Darmstadt, Germany
 
  The systematic studies of transverse profile measurement were carried out with scintillation screens such as single crystals (CsI:Tl, YAG:Ce), powder screens (P43, P46), ceramics (Al2O3, Al2O3:Cr, Y and Mg doped ZrO2), Ce doped (0.3%) and undoped glasses (Herasil). Different ion beams like C, Ne, Ta, and U accelerated to energy of 300 MeV/u were extracted from the heavy ion synchrotron at GSI within 0.3 s for intensities from 104 to 109 particles per pulse. The image of each beam pulse was recorded by a CCD camera and individually evaluated. The recorded image profiles show a reproducible dependence on scintillation screen. A difference in image width up to 50% is noticed between CsI:Tl and Herasil. The detailed investigation shows that the powder screens P43 and P46, ceramics Al2O3 and Al2O3:Cr reproduce the beam width within a difference of  ± 4% for all intensities. The light yield from the screens scales linearly over 5 orders of magnitude of particle intensity. The light yield per energy deposition by a single ion was calculated for different ion beams. This normalized light yield is a factor of 2 higher for Carbon ions compared to Uranium.  
 
TUPG042 High Intensity Effects on Betatron Tune at GSI SIS-18 219
 
  • R. Singh, O. Chorniy, P. Forck, R. Haseitl, W. Kaufmann, P. Kowina, K. Lang
    GSI, Darmstadt, Germany
  • T. Weiland
    TEMF, TU Darmstadt, Darmstadt, Germany
 
  Funding: This work is supported by DITANET (novel DIagnostic Techniques for future particle Accelerators: A Marie Curie Initial Training NETwork),Project Number ITN-2008-215080
The tune measurement system (TOPOS) at GSI SIS-18 consists of, a band limited noise exciter which excites coherent betatron oscillations in the bunched beam; Fast ADCs to digitize the BPM signals at 125 MSa/s and FPGAs to calculate position from the digitized BPM signals. Baseband tune is thus determined by Fourier transformation of the individual bunch position data. Several tune measurement campaigns were performed with U73+ and Ar18+ ion beam at highest achievable intensities of 2x109 and 2.5x1010 respectively using TOPOS. The goal of these measurements was to understand the high current effects on the tune spectra. Substantial modification of the tune spectra were observed and attributed to the bunch head tail oscillations after further investigations. Coherent tune shift in dependence of beam intensity were also measured. This contribution reports on the modified tune spectra, corresponding space charge effects and further experimental details.