Paper |
Title |
Page |
MOPG022 |
NSLS2 Beam Position Monitor Calibration |
77 |
|
- W.X. Cheng, B. Bacha, O. Singh
BNL, Upton, Long Island, New York, USA
|
|
|
To get accurate beam position measurements along the accelerator complex, beam position monitor (BPM) sensitivity and electric offset need to be calibrated. A good calibration is essential for day one commissioning and large beam offset measurements. For various type of BPMs used in NSLS2, the sensitivity curves were calculated and fitting by high order polynomial fit. Fitting errors are typically less than 50um. BPM electric offsets are measured using four port network analyzer. These offset values will supply a good reference for beam based alignment.
|
|
|