A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Rakhno, I.

Paper Title Page
TUPAS016 Collimation System Design for Beam Loss Localization with Slipstacking Injection in the Fermilab Main Injector 1688
 
  • A. I. Drozhdin, B. C. Brown, D. E. Johnson, I. Kourbanis, N. V. Mokhov, I. Rakhno, V. Sidorov
    Fermilab, Batavia, Illinois
  • K. Koba
    KEK, Ibaraki
 
  Results of modeling with the STRUCT and MARS15 codes of beam loss localization and related radiation effects are presented for the slipstacking injection to the Fermilab Main Injector. Simulations of proton beam loss are done using multi-turn tracking with realistic accelerator apertures, nonlinear fields in the accelerator magnets and time function of the RF manipulations to explain the results of beam loss measurements. The collimation system consists of one primary and four secondary collimators. It intercepts a beam power of 1.6 kW at a total scraping rate of 5%, with a beam loss rate in the ring outside the collimation region of 1 W/m or less. Based on thorough energy deposition and radiation modeling, a corresponding collimator design was developed that satisfies all the radiation and engineering constraints.  
TUPAS018 A Conceptual Design of an Internal Injection Absorber of 8 GeV H- Injection into the Fermilab Main Injector 1694
 
  • D. E. Johnson, A. Z. Chen, I. Rakhno
    Fermilab, Batavia, Illinois
 
  Funding: Work supported by Universities Research Association, Inc. under contract No. DE-AC02-76CH03000 with the U. S. Dept. of Energy.

A 8 GeV H- superconducting linac has been proposed as an alternative injector for the Main Injector to support a 2 MW Neutrino program. An injection absorber is required to accept protons generated after the secondary stripping foil which will intercept the un-stripped H- and H0 particles after the MI primary foil injection point. The motivations underlying the choice of a compact internal absorber over an external absorber will be discussed. We show that using a high-Z material (tungsten) for the inner shielding allows the construction a compact absorber that can take a very intense beam and fits within the existing enclosure. The absorber requirements and a shielding design and the results of energy deposition calculations are presented.

 
WEPMN106 Design and Commissioning of Fermilab's Vertical Test Stand for ILC SRF Cavities 2283
 
  • J. P. Ozelis, R. H. Carcagno, C. M. Ginsburg, Y. Huang, B. Norris, T. Peterson, V. Poloubotko, R. Rabehl, I. Rakhno, C. Reid, D. A. Sergatskov, C. Sylvester, M. Wong, C. Worel
    Fermilab, Batavia, Illinois
 
  Funding: Operated by Universities Research Association, Inc. for the U. S. Department of Energy under contract DE-AC02-76CH03000

As part of a program to improve cavity performance reproducibility for the ILC, Fermilab is developing a facility for vertical testing of SRF cavities. It operates at a nominal temperature of 2K, using an existing cryoplant that can supply LHe in excess of 20g/sec and provides steady-state bath pumping capacity of 125W at 2K. The below-grade cryostat consists of a 4.9m long vacuum vessel and 4.5m long LHe vessel. The cryostat is equipped with external and internal magnetic shielding to reduce the ambient magnetic field to <10mG. Internal fixed and external movable radiation shielding ensures that radiation levels from heavily field-emitting cavities remain low. In the event that radiation levels exceed allowable limits, an integrated personnel safety system consisting of RF switches, interlocks, and area radiation monitors disables RF power to the cavity. In anticipation of increased throughput requirements that may be met with additional test stand installations, sub-systems have been designed to be easily upgradeable or to already meet these anticipated needs. Detailed facility designs, performance during system commissioning, and results from initial cavity tests are presented.