Paper |
Title |
Page |
RPPE015 |
Diagnostics and Protection Control for IREN Linac Test Facility
|
|
|
- V.N. Zamriy
JINR, Dubna, Moscow Region
|
|
|
The diagnostic and protection control systems for the full-scale test facility of the linear electron accelerator are constructed according to the project on pulsed neutron source IREN. Combined control schemes of timed diagnostics of a duty cycle and real-time protection control are created for the linac test facility. Applicability of the diagnostics systems of cycle parameters and deviations of a status for control of the mode of protection is shown. Multichannel control modules of the protection system have been developed for logging and diagnostics of a status change, the alarms and control of a mode of operation. The applied multiway controllers for duty protection with fast locking of cycles of the IREN linac are presented.
|
|