Paper | Title | Page |
---|---|---|
MPPE021 | Non-Linear Beam Transport System for the LENS 7 MeV Proton Beam | 1704 |
|
||
Funding: This work has been supported by the National Science Foundation under grants DMR-0220560 and DMR0320627, by the Indiana 21st Century Science and Technology Fund, and by the Department of Defense. A beam transport system has been designed to carry a high-intensity low-emittance proton beam from the exit of the RFQ-DTL acceleration system of the Indiana University Low Energy Neutron System (LENS)* to the neutron production target. The goal of the design was to provide a beam of uniform density over a 3cm by 3cm area at the target. Two octupole magnets** are employed in the beam line to provide the necessary beam phase space manipulations to achieve this goal. First order calculations were done using TRANSPORT and second order calculations have been performed using TURTLE. Second order simulations have been done using both a Gaussian beam distribution and a particle set generated by calculations of beam transport through the RFQ-DTL using PARMILA. Comparison of the design characteristics with initial measurements from the LENS commissioning process will be made. *V.P. Derenchuk et al., "The LENS 7 MeV, 10mA proton Linac," these proceedings. **E. Kashy & B. Sherrill, Nuclear Instruments and Methods in Physics Research, B26 (1987) p. 610. |
||
FPAE051 | Performance of a CW RFQ Injector for the IUCF Cyclotron | 3179 |
|
||
Funding: The State of Indiana, Indiana University, and the DOE (Grant No DE-FG-02000ER62966) supported this work. A 750 keV RFQ proton pre-injector was installed in place of a 600 keV Cockroft-Walton high voltage terminal for the IUCF k220 Cyclotron.* The pre-injector consists of a 20 keV microwave ion source and LEBT, a unique design 750 keV CW RFQ, and a short transfer beam line to the k15 injector cyclotron center region.** This pre-injector system was installed and commissioned in June of 2003 and is now in routine service as the sole injection system to the cyclotrons. This contribution will discuss the performance of the CW RFQ pre-injector and the transmission properties of the beam through the cyclotrons. *D.L.Friesel, et al., App. of Acc. in Res. and Ind., eds. J.L. Duggan and I.L. Morgan, Denton, 651(2000). **V.P. Derenchuk, et al., 2003 Particle Accelerator Conference, Portland, OR, (2003), edited by A. Jackson and E. Lee. |
||
FPAE052 | The LENS 7 MeV, 10 mA Proton Linac | 3200 |
|
||
Funding: This work has been supported by the National Science Foundation under grants DMR-0220560, and DMR-0320627, by the Indiana 21st Century Science and Technology Fund, and by the Department of Defense. The Indiana University Cyclotron Facility (IUCF) has constructed and placed in operation a Low Energy Neutron Source (LENS) using a 10 mA, 7 MeV proton beam incident on a beryllium target. The proton delivery system (PDS) consists of a 25 keV proton injector, an AccSys Technology, Inc. PL7 Linac* and a beam transport line with non-linear beam spreading.** The accelerator and beamline equipment used in this construction are refurbished and upgraded components from the IUCF CIS/Cooler synchrotron*** facility. After commissioning the beam current at 7 MeV will be 10 mA with a pulse width of up to 300 μs and > 1% duty factor. The PDS was constructed and commissioning started in 2004. First operating results will be described. *D.L. Friesel and W. Hunt, Linac98, pp61-63. **W.P. Jones, et. al., "Non-Linear Beam Transport System for the LENS 7 MeV Proton Beam," this proceedings. ***D.L. Friesel, et. al., EPAC2000, pp. 539-541. |