Paper |
Title |
Page |
RPAP036 |
A Compact 5 MeV S-Band Electron Linac Based X-Ray Source for Industrial Radiography
|
2428 |
|
- L. Auditore, R.C. Barnà, D. De Pasquale, U. Emanuele, A. Trifirò, M. Trimarchi
INFN & Messina University, S. Agata, Messina
- A. Italiano
INFN - Gruppo Messina, S. Agata, Messina
|
|
|
A compact and reliable X-ray source, based on a 5 MeV, 1 kW, S-band electron linac, has been set up at the Dipartimento di Fisica, Universit\a di Messina. This source, coupled with a GOS scintillator screen and a CCD camera, represents an innovative transportable system for industrial radiography and X-ray tomography. Optimization of the parameters influencing the e-gamma conversion and the X-ray beam characteristics have been studied by means of the MCNP-4C2 code. The converter choice is the result of the study of the e-gamma conversion performances for different materials and materials thicknesses. Also the converter position with respect to the linac exit window was studied. The chosen converter consists in a Ta-Cu target inserted close to the linac window. The Cu layer acts as a filter both on the electrons from the source and on the low energy X-rays. The X-ray beam angular profile was studied by means of GafChromic films with and without collimation. In the final source project, a collimation system provides a 14 cm diameter X-ray spot at the sample position and first radiographyc results were obtained by inspecting different density materials and thicknesses.
|
|