Author: Yang, C.K.
Paper Title Page
TUPAB104 Optimized Undulator to Generate Low Energy Photons From Medium to High Energy Accelerators 1556
 
  • T.Y. Chung, M.-S. Chiu, J.C. Huang, C.-S. Hwang, J.C. Jan, C.K. Yang
    NSRRC, Hsinchu, Taiwan
  • H.W. Luo
    NTHU, Hsinchu, Taiwan
 
  While emitting low energy photons from a medium or high energy storage ring, the on-axis heat load on the beam line optics can become a critical issue. In addition, the heat load in the bending magnet chamber, especially in the vertical and circular polarization mode of operation may cause some concern. In this work, we compare the heat loads for the APPLE-II and the Knot-APPLE, both optimized to emit 10 eV photons from the 3 GeV TPS. Under this constraint the heat load analysis, synchrotron radiation performance and features in various polarization modes are presented. Additional consideration is given to beam dynamics effect.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-TUPAB104  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPAB105 Field Measurement System for a Cryogenic Permanent Magnet Undulator in TPS 1559
 
  • C.K. Yang, C.H. Chang, T.Y. Chung, W.H. Hsieh, J.C. Huang, C.-S. Hwang
    NSRRC, Hsinchu, Taiwan
 
  Short period in-vacuum, permanent magnet undulators operating at cryogenic temperatures are being developed worldwide to serve as brilliant and coherent light sources for medium energy storage rings. A hybrid cryogenic permanent magnet undulator (CU) with PrFeB magnets has now been designed and constructed at NSRRC [1]. To characterize the performance and to determine magnetic field errors after cool down poses some technical chal-lenges compared to room temperature undulators. A new system combining a Hall probe and a stretched wire has been designed to measure the field integrals, trajectory, phase errors, and K value under low temperature and vacuum conditions. Field measurements in this cryogenic undulator will be performed around 77 K as well as at room temperature, making temperature dependent calibra-tion of the Hall probes necessary. The main features and improvement of the measurement and calibration system are presented.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-TUPAB105  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPAB106 Development of a Cryogenic Permanent Magnet Undulator for the TPS 1562
 
  • J.C. Huang, C.H. Chang, T.Y. Chung, C.-S. Hwang, J.C. Jan, C.S. Yang, C.K. Yang
    NSRRC, Hsinchu, Taiwan
  • H. Kitamura
    RIKEN SPring-8 Center, Sayo-cho, Sayo-gun, Hyogo, Japan
 
  Development of a cryogenic permanent magnet undu-lator (CPMU) at the Taiwan Photon Source (TPS) is the most recent activity toward a new light source for the Phase-II beamlines. A hybrid-type CPMU with a period length of 15 mm is under construction with PrFeB permanent-magnet materials. A maximum effective magnetic field of 1.77 T at a gap of 3 mm is expected when the magnets (PMs) are cooled down around 77 K. The features desired for the TPS CPMU are low-intrinsic-phase-error characteristics and high thermal budget for various kinds of heat loads. The design of the TPS CPMU is discussed in this paper.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-TUPAB106  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)