Author: Schreiber, S.
Paper Title Page
MOPAB044 X-Band TDS Project 184
 
  • B. Marchetti, R.W. Aßmann, B. Beutner, J. Branlard, F. Christie, R.T.P. D'Arcy, W. Decking, U. Dorda, J. Herrmann, M. Hoffmann, M. Hüning, O. Krebs, G. Kube, S. Lederer, F. Ludwig, F. Marutzky, D. Marx, J. Osterhoff, I. Peperkorn, S. Pfeiffer, F. Poblotzki, J. Rönsch-Schulenburg, J. Rothenburg, H. Schlarb, M. Scholz, S. Schreiber, M. Vogt, A. Wagner, T. Wilksen, K. Wittenburg
    DESY, Hamburg, Germany
  • M. Bopp, H.-H. Braun, P. Craievich, M. Pedrozzi, E. Prat, S. Reiche, K. Rolli, R. Zennaro
    PSI, Villigen PSI, Switzerland
  • N. Catalán Lasheras, A. Grudiev, G. McMonagle, W. Wuensch
    CERN, Geneva, Switzerland
 
  Based on the success of the X-Band Transverse Deflecting Structure (TDS) diagnostic at LCLS*, a collaboration between DESY, PSI and CERN has formed with the aim of developing and building an advanced modular X-Band TDS system. The designed TDS has the new feature of providing variable polarization of the deflecting field**. The possibility of changing the orientation of the streaking field of the TDS to an arbitrary azimuthal angle allows for 3D characterization of the phase space using tomographic methods***. Moreover the complete 6D characterization of the beam phase space is possible by combining this technique with quadrupole scans and a dipole spectrometer. As this new cavity design requires very high manufacturing precision to guarantee highest azimuthal symmetry of the structure to avoid the deterioration of the polarization of the streaking field, the high precision tuning-free assembly procedures developed at PSI for the SwissFEL C-band accelerating structures will be used for the manufacturing****. The high-power rf system is based on the CERN-based X-band test stands. We summarize in this work the status of the projects and its main technical parameters.
* C. Behrens et al. , Nat. Comm. 4762 (2014).
** A. Grudiev, CLIC-note-1067 (2016).
*** D. Marx et al., contribution to this conference proceedings.
**** U. Ellenberger et al., FEL 2013, TUPS017.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-MOPAB044  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPAB017 Generation of Ultra-Short Electron Bunches and FEL Pulses and Characterization of Their Longitudinal Properties at FLASH2 2600
 
  • F. Christie, J. Rönsch-Schulenburg, S. Schreiber, M. Vogt
    DESY, Hamburg, Germany
 
  The free-electron laser in Hamburg (FLASH) is a user facility, delivering soft X-ray radiation, consisting of two beam lines, FLASH1 and FLASH2. The injector and the main linac are shared between both beam lines. Starting in 2014, FLASH2 has been commissioned for user operation. Currently, there is no hardware installed for the direct measurement of the electron bunch length nor the photon pulse duration at FLASH2. Exact knowledge of the pulse duration is essential for time-resolved user experiments performed at FLASH. Therefore, we are designing a modified beam line, containing a new type of X-band deflecting cavity* and a dipole, downstream of the FLASH2 undulator, to map the longitudinal phase space onto a beam screen. Anticipating the feasibility of measuring the longitudinal phase space with high resolution, a study on optimizing the free-electron laser (FEL) performance for shortest bunches is ongoing.
*B. Marchetti et al., X-Band TDS project, contribution to these conference proceedings
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-WEPAB017  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPAB021 Experience with Multi-Beam and Multi-Beamline FEL-Operation 2615
 
  • J. Rönsch-Schulenburg, B. Faatz, K. Honkavaara, M. Kuhlmann, S. Schreiber, R. Treusch, M. Vogt
    DESY, Hamburg, Germany
 
  DESY's free-electron laser FLASH provides soft X-ray pulses for scientific users at wavelengths down to 4 nm simultaneously in two undulator beamlines. They are driven by a common linear superconducting accelerator with a beam energy of up to 1.25 GeV. The superconducting technology allows the acceleration of electron bunch trains of several hundred bunches with a spacing of 1 microsecond or more and a repetition rate of 10 Hz. A fast kicker-septum system directs one part of the bunch train to FLASH1 and the other part to FLASH2 keeping the full 10 Hz repetition rate for both. The unique setup of FLASH allows independent FEL pulse parameters for both beamlines. In April 2016, simultaneous operation of FLASH1 and FLASH2 for external users started. This paper reports on our operating experience with this type of multi-beam, multi-beamline set-up.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-WEPAB021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPAB023 First Operation of a Harmonic Lasing Self-Seeded FEL 2621
 
  • E. Schneidmiller, B. Faatz, M. Kuhlmann, J. Rönsch-Schulenburg, S. Schreiber, M. Tischer, M.V. Yurkov
    DESY, Hamburg, Germany
 
  Harmonic lasing is a perspective mode of operation of X-ray FEL user facilities that allows to provide brilliant beams of higher energy photons for user experiments. Another useful application of harmonic lasing is so called Harmonic Lasing Self-Seeded Free Electron Laser (HLSS FEL) that allows to improve spectral brightness of these facilities. In the past, harmonic lasing has been demonstrated in the FEL oscillators in infrared and visible wavelength ranges, but not in high-gain FELs and not at short wavelengths. In this paper we report on the first evidence of the harmonic lasing and the first operation of the HLSS FEL at the soft X-ray FEL user facility FLASH in the wavelength range between 4.5 nm and 15 nm. Spectral brightness was improved in comparison with Self-Amplified Spontaneous emission (SASE) FEL by a factor of six in the exponential gain regime. A better performance of HLSS FEL with respect to SASE FEL in the post-saturation regime with a tapered undulator was observed as well. The first demonstration of harmonic lasing in a high-gain FEL and at a short wavelength paves the way for a variety of applications of this new operation mode in X-ray FELs.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-WEPAB023  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPAB025 Status of the Soft X-Ray Free Electron Laser FLASH 2628
 
  • M. Vogt, B. Faatz, K. Honkavaara, M. Kuhlmann, J. Rönsch-Schulenburg, S. Schreiber, R. Treusch
    DESY, Hamburg, Germany
 
  The superconducting free-electron laser user facility FLASH at DESY in Hamburg, routinely produces several thousand photon pulses per second. The operational parameters cover a wavelength range from 90 nm down to 4 nm with pulse energies from several uJ up to 1 mJ and with pulse durations of several hundred fs down to a few fs. The FLASH injector and linac drives two undulator beam lines (FLASH1, FLASH2) and therefore FLASH is capable of serving 2 independent experiments with photon pulse (sub-) trains of several 100 bunches at the full train repetition frequency of 10 Hz. We summarize here the highlights of the user operation at FLASH1/2 and the study program (machine development and FEL optimization) of the FLASH facility.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-WEPAB025  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)