THPVA140 Superconducting Gantry Design for Proton Tomography 4795
 
  • E. Oponowicz, H.L. Owen
    UMAN, Manchester, United Kingdom
 
  Precise proton therapy planning can be assisted by augmenting conventional medical imaging techniques with proton computed tomography (pCT). For adults this requires an incident proton energy up to around 330 MeV, requiring superconducting magnets if an imaging gantry is to replace a conventional 230-250 MeV gantry in the same space. Here we present optics considerations for a superconducting gantry to deliver 330 MeV protons within the context of the future Christie Hospital proton therapy centre, where it is proposed to increase the proton energy in the future with a booster linac.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-THPVA140  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)