Author: Michel, P.
Paper Title Page
MOZB1 First Results with the Novel Peta-Watt Laser Acceleration Facility in Dresden 48
 
  • U. Schramm, D. Albach, C. Bernert, S. Bock, F. Brack, J. Branco, M.H. Bussmann, J.P. Couperus, A.D. Debus, C. Eisenmann, M. Garten, R. Gebhardt, S. Grams, U. Helbig, A. Huebl, A. Irman, A. Köhler, J.M. Krämer, S. Kraft, F. Kroll, J. Metzkes, L. Obst, R.G. Pausch, M. Rehwald, H.P. Schlenvoigt, M. Siebold, K. Steiniger, O. Zarini, K. Zeil
    Helmholtz-Zentrum Dresden-Rossendorf (HZDR), Institute of Radiation Physics, Dresden, Germany
  • T. Kluge, M. Kuntzsch, U. Lehnert, M. Löser, P. Michel, R. Sauerbrey
    HZDR, Dresden, Germany
 
  Applications of laser plasma accelerated particle beams ranging from driving of light sources to radiation therapy require the scaling of beam energy and charge as well as reproducible operating conditions. Both issues have motivated the development of novel table-top class Petawatt laser systems (e.g., 30J pulse energy in 30fs) with unprecedented pulse control, here represented by the Draco-PW system recently commissioned at HZDR Dresden. First results will be presented on laser wakefield electron acceleration where in the beam loading regime high bunch charges in the nC range could be efficiently accelerated with good beam quality, and on proton acceleration where pulsed magnet beam transport ensured depth dose distributions allowing for tumor irradiation in animal models.  
slides icon Slides MOZB1 [4.059 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-MOZB1  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPIK003 Improvement of the Photoemission Efficiency of Magnesium Photocathodes 500
 
  • R. Xiang, A. Arnold, P.N. Lu, P. Michel, P. Murcek, J. Teichert, H. Vennekate
    HZDR, Dresden, Germany
  • P. Patra
    IUAC, New Delhi, India
 
  Funding: The work is supported by the European Community under the FP7 programme (EuCARD-2) and by the German Federal Ministry of Education and Research (BMBF) grant 05K12CR1.
To improve the quality of photocathodes is one of the critical issues in enhancing the stability and reliability of photo-injector systems. Presently the primary choice is to use metallic photocathodes for the ELBE SRF Gun-II to reduce the risk of contamination of the superconducting cavity. Magnesium has a low work function (3.6 eV) and shows high quantum efficiency (QE) up to 0.3 % after laser cleaning. The SRF Gun II with an Mg photocathode has successfully provided electron beam for ELBE users. However, the present cleaning process with a high intensi-ty laser (activation) is time consuming and generates unwanted surface roughness. This paper presents the investigation of alternative surface cleaning procedures, such as thermal treatment. The QE and topography of Mg samples after treatment are reported.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-MOPIK003  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPAB033 Design of a Stripline Kicker for the ELBE Accelerator 1393
 
  • Ch. Schneider, A. Arnold, J. Hauser, P. Michel, G.S. Staats
    HZDR, Dresden, Germany
 
  ELBE is a linac based cw electron accelerator serving different secondary beams one at a time. Depending on the user demand the bunch repetition rate may vary from single pulse up to 13 MHz. For the future different end stations should be served simultaneously, hence specific bunch patterns have to be kicked to other beam-lines. To use e.g. one bunch out of the bunch train very short kicking durations have to be realized. The variability of the bunch pattern and the frequency resp. switching time are one of the main arguments for a stripline-kicker combined with HV-switches as basic concept. A nearly homogenous field in the kicker has to be realized for uniform deflection of the electron bunch and emittance grow of the bunch has to be kept as low as possible. Furthermore the fast switching ability of the kicker demands for a fast decay of the HV-pulse resp. its reflections in the structure implying a specific design of the kicker elements. For this reason a design with two tapered active electrodes and two ground fenders was optimized in time and frequency domain with the software package CST. Additionally a first prototype was manufactured for laboratory and first beam-line tests.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-TUPAB033  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPVA081 Radiation Tests of Aerospace Components at ELBE 4641
 
  • Ch. Schneider, D. Bemmerer, P. Michel, D. Stach
    HZDR, Dresden, Germany
 
  The cw electron accelerator ELBE operates mainly in the beam energy range 6 to 32 MeV and beam current range 1μA to 1mA. For most experiments a thermionic gun is used as electron source. The cw electron pulse structure so as the pulse charge is realized by applying electrical pulses with specific amplitudes and frequencies on the grid of the gun. The standard cw operation frequency is 13 MHz but can be divided sequentially by the factor 2 down to 101 kHz. For very special pulse structures a so called single pulser module exist performing different patterns also with dark current suppression via a macro pulser gate. For evaluating the performance and hardness under irradiation of e.g. aerospace components much lower doses respectively currents lower than the μA range are required. Furthermore reproducible and stable doses in a specific area for consecutively radiation of samples are necessary. In the presentation the investigations and concepts used at ELBE for the irradiation of different aerospace components are described.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-THPVA081  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)