Paper | Title | Page |
---|---|---|
TUPIK108 | Beam Based Alignment Studies for the CLARA FEL Test Facility | 1971 |
|
||
The CLARA (Compact Linear Accelerator for Research and Applications) test facility is designed to experimentally demonstrate innovative FEL schemes for future light source applications. Such schemes can place strict requirements on the accelerator beam properties as well as the relative alignment of the beam in the FEL radiators and modulators. Beam-based alignment (BBA) of the FEL section is therefore an operational requirement for all advanced FEL facilities. In this paper we demonstrate results of CLARA BBA simulations, and also report initial simulation results from the use of non-linear algorithms to optimise the FEL performance directly. | ||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-TUPIK108 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
THPAB059 | CSR and Space Charge Studies for the CLARA Phase 1 Beamline | 3851 |
|
||
The installation of Phase 1 of CLARA, the UK's new FEL test facility, is currently underway at Daresbury Laboratory. When completed, it will be able to deliver 45 MeV electron beams to the pre-existing VELA beamline, which runs parallel. Phase 1 consists of a 10 Hz photocathode gun, a 2 m long S-band travelling wave linac, a spectrometer line, and associated optics and diagnostics. A detailed study into the beam dynamics of the lattice is presented, with a focus towards the effects of space charge and coherent synchrotron radiation on the electron bunch. Simulations disagreed with predictions from a one-dimensional model of coherent radiation, and this disagreement is believed to be due to a violation of the Derbenev criterion. | ||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-THPAB059 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
THPVA139 | Relative Insensitivity to Inhomogeneities on Very High Energy Electron Dose Distributions | 4791 |
|
||
Funding: Science and Technology Facilities Council, United Kingdom Cockroft Institute, United Kingdom Christie Hospital, Manchester, United Kingdom We investigated the effects of heterogeneous regions on dose deposition of very high-energy electrons (VHEE) using both Geant4 simulations and experiments performed at the CALIFES facility at CERN. Small air and acetal plastic (bone equivalent) cavities were embedded in a water phantom and irradiated with a 197 MeV electron beam. Experimentally determined transverse dose profiles were acquired using radiation sensitive EBT3 Gafchromic films embedded in the water phantom at various depths. EBT3 Gafchromic films were found to be a suitable dosimeter for relative dose dosimetry of VHEE beams. Simulated and measured results were found to be consistent with each other and the largest discrepancy was found to be no more than 5%. Dose profiles of VHEE beams were found to be relatively insensitive to embedded high and low density geometries. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-THPVA139 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |