Paper |
Title |
Page |
THPIK005 |
RF Conditionning of the Spiral 2 CW RFQ |
4114 |
|
- O. Piquet, Y. Lussignol
CEA/DSM/IRFU, France
- M. Desmons, A.C. France, P. Galdemard
CEA/IRFU, Gif-sur-Yvette, France
- M. Di Giacomo, R. Ferdinand, J.-M. Lagniel
GANIL, Caen, France
|
|
|
The SPIRAL2 RFQ is designed to accelerate light and heavy ions with A/Q from 1 to 3 at 0.73 MeV/A. The nominal beam intensities are up to 5 mA CW for both proton and deuteron beams and up to 1 mA CW for heavier ions. The four-vane cavity is made with 5 1-meter long sections mechanically assembled, it works at 88 MHz and is powered up to 180 kW CW to achieve the nominal vane voltage of 113.7 kV for A/Q = 3 ions. This paper describes the RF conditioning of the RFQ at GANIL with the setting of its RF systems and cooling system used to tune the cavity resonance frequency.
|
|