Author: Awida, M.H.
Paper Title Page
MOPVA113 RF Quality Control of SRF Cavities for LCLS-II Cryo-Modules 1108
 
  • M.H. Awida, P. Berrutti, T.N. Khabiboulline, A. Lunin, V.P. Yakovlev
    Fermilab, Batavia, Illinois, USA
 
  Funding: *Operated by Fermi Research Alliance, LLC, under Contract DE-AC02-07CH11359 with the U.S. DOE
LCLS-II project is gearing up to build 36 cryo-modules of the 1.3 GHz TESLA style cavities. Half of those cryomodules are being built at Fermilab, while JLAB is carrying the production of the other half. In this paper, we present the process of quality controlling the RF performance of cavities until they are qualified for the final string assembly at Fermilab. The RF quality control process includes monitoring the frequency spectrum of each cavity and tuning/adjusting of the notch frequencies before testing at the Vertical Test Stand (VTS). Measured data during income QC is presented and in addition we show the notch frequencies before and after testing at the VTS. Moreover, we report some of the RF measurements taken while the cavity is cooled down to 2K temperature.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-MOPVA113  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)