Author: Artoos, K.
Paper Title Page
MOPVA096 The Crab Cavities Cryomodule for SPS Test 1081
 
  • C. Zanoni, A. Amorim Carvalho, K. Artoos, S. Atieh, K. Brodzinski, R. Calaga, O. Capatina, T. Capelli, F. Carra, L. Dassa, T. Dijoud, K. Eiler, G. Favre, P. Freijedo Menendez, M. Garlaschè, L. Giordanino, S.A.E. Langeslag, R. Leuxe, H. Mainaud Durand, P. Minginette, M. Narduzzi, V. Rude, M. Sosin, J.S. Swieszek
    CERN, Geneva, Switzerland
  • T.J. Jones, N. Templeton
    STFC/DL, Daresbury, Warrington, Cheshire, United Kingdom
 
  RF Crab Cavities are an essential part of the HL-LHC upgrade. Two concepts of such systems are being developed: the Double Quarter Wave (DQW) and the RF Dipole (RFD). A cryomodule with two DQW cavities is in advanced fabrication stage at CERN for their tests with protons in the SPS during the 2018 run. The cavities must be operated at 2 K, without excessive heat loads, in a low magnetic environment and in compliance with CERN safety guidelines on pressure and vacuum systems. A large set of components, such as a thermal shield, a two layers magnetic shield, RF lines, helium tank and tuner is required for the successful and safe operation of the cavities. The assembly of all these components with the cavities and their couplers forms the cryomodule. An overview of the design and fabrication strategy of this cryomodule is presented. The main components are described along with the present status of cavity fabrication and processing and cryomodule assembly. The lesson learned from the prototypes, the helium tank above all, and first manufactured systems is also included.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-MOPVA096  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPIK077 Main Achievements of the PACMAN Project for the Alignment at Micrometric Scale of Accelerator Components 1872
 
  • H. Mainaud Durand, K. Artoos, M.C.L. Buzio, D. Caiazza, N. Catalán Lasheras, A. Cherif, I.P. Doytchinov, J.-F. Fuchs, A. Gaddi, N. Galindo Munoz, J. Gayde, S.W. Kamugasa, M. Modena, P. Novotny, S. Russenschuck, C. Sanz, G. Severino, D. Tshilumba, V. Vlachakis, M. Wendt, S. Zorzetti
    CERN, Geneva, Switzerland
  • A. Faus-Golfe
    LAL, Orsay, France
 
  Funding: The research leading to these results has received funding from the European Union's 7th Framework Programme Marie Curie actions, grant agreement PITN-GA-2013-606839.
The objectives of the PACMAN* project are to improve the precision and accuracy of the alignment of accelerator components. Two steps of alignment are concerned: the fiducialisation, i.e. the determination of the reference axis of components w.r.t alignment targets, and the initial alignment of components on a common support assembly. The main accelerator components considered for the study are quadrupoles, 15 GHz BPM and RF structures from the Compact LInear Collider (CLIC) project. Different methods have been developed to determine the reference axis of these components with a micrometric accuracy, as well as to determine the position of this reference axis in the coordinate frame of the common support assembly. The tools and methods developed have been validated with success on dedicated test setups using CLIC components. This paper will provide a compilation of the main achievements and results obtained.
* PACMAN is an acronym for a study on Particle Accelerator Components' Metrology and Alignment to the Nanometre scale.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-TUPIK077  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)