Author: Alomari, K.Alomari.
Paper Title Page
MOPVA050 Setup of a Spatially Resolving Vector Magnetometry System for the Investigation of Flux Trapping in Superconducting Cavities 975
SUSPSIK099   use link to see paper's listing under its alternate paper code  
 
  • B. Schmitz, K.Alomari. Alomari, J. Knobloch, O. Kugeler, J.M. Köszegi, Y. Tamashevich
    HZB, Berlin, Germany
 
  Flux trapping is the major contribution to the residual resistance of superconducting cavities. In order to gain a better understanding of the mechanisms involved and aiming at an eventual minimization of trapped flux, a measurement setup based on AMR sensors was devised that allows for monitoring the magnetic field vector at various positions near the cavity surface. First results of the efforts are presented.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2017-MOPVA050  