Paper |
Title |
Page |
MOPLS024 |
RHIC Performance as Polarized Proton Collider in Run-6
|
592 |
|
- V. Ptitsyn, L. Ahrens, M. Bai, D.S. Barton, J. Beebe-Wang, M. Blaskiewicz, A. Bravar, J.M. Brennan, K.A. Brown, D. Bruno, G. Bunce, R. Calaga, P. Cameron, R. Connolly, T. D'Ottavio, J. DeLong, K.A. Drees, A.V. Fedotov, W. Fischer, G. Ganetis, H. Hahn, T. Hayes, H.-C. Hseuh, H. Huang, P. Ingrassia, D. Kayran, J. Kewisch, R.C. Lee, V. Litvinenko, A.U. Luccio, Y. Luo, W.W. MacKay, Y. Makdisi, N. Malitsky, G.J. Marr, A. Marusic, R.J. Michnoff, C. Montag, J. Morris, T. Nicoletti, B. Oerter, F.C. Pilat, P.H. Pile, T. Roser, T. Russo, J. Sandberg, T. Satogata, C. Schultheiss, S. Tepikian, D. Trbojevic, N. Tsoupas, J.E. Tuozzolo, A. Zaltsman, A. Zelenski, K. Zeno, S.Y. Zhang
BNL, Upton, Long Island, New York
|
|
|
The Relativistic Heavy Ion Collider in Run-6 was operating in polarized proton mode. With two Siberian Snakes per ring, the polarized protons were brought into collisions at 100 Gev and 31.2 Gev energies. The control of polarization orientation at STAR and PHENIX experiments was done using helical spin rotators. Physics studies were conducted with longitudinal, vertical and radial beam polarization at collision points. This paper presents the performance of RHIC as a polarized proton collider in the Run-6 with emphasis on beam polarization and luminosity issues.
|
|
MOPLS025 |
Experience in Reducing Electron Cloud and Dynamic Pressure Rise in Warm and Cold Regions in RHIC
|
595 |
|
- S.Y. Zhang, L. Ahrens, J.G. Alessi, M. Bai, M. Blaskiewicz, P. Cameron, R. Connolly, K.A. Drees, W. Fischer, J. Gullotta, P. He, H.-C. Hseuh, H. Huang, R.C. Lee, V. Litvinenko, W.W. MacKay, C. Montag, T. Nicoletti, B. Oerter, F.C. Pilat, V. Ptitsyn, T. Roser, T. Satogata, L. Smart, L. Snydstrup, S. Tepikian, P. Thieberger, D. Trbojevic, J. Wei, K. Zeno
BNL, Upton, Long Island, New York
|
|
|
Significant improvement has been achieved for reducing electron cloud and dynamic pressure rise at RHIC over several years; however, there remain to be factors limiting luminosity. The large scale application of non-evaporable getter (NEG) coating in RHIC has been proven effective in reducing electron multipacting and dynamic pressure rise. This will be reported together with the study of the saturated NEG coatings. Since beams with increased intensity and shorter bunch spacing became possible in operation, the electron cloud effects on beam, such as the emittance growth,are an increasing concern. Observations and studies are reported. We also report the study results relevant to the RHIC electron cloud and pressure rise improvement, such as the effect of anti-grazing ridges on electron cloud in warm sections, and the effect of pre-pumping in cryogenic regions.
|
|
THPCH197 |
Analysis of Availability and Reliability in RHIC Operations
|
3257 |
|
- F.C. Pilat, P. Ingrassia, R.J. Michnoff
BNL, Upton, Long Island, New York
|
|
|
RHIC has been successfully operated for five years as a collider for different species, ranging from heavy ions including gold and copper, to polarized protons. We present a critical analysis of reliability data for RHIC that not only identifies the principal factors limiting availability but also evaluates critical choices at design times and assess their impact on present machine performance. RHIC availability data are compared to similar high-energy colliders and synchrotron light sources. The critical analysis of operations data is the basis for studies and plans to improve RHIC machine availability beyond the 60% typical of high-energy collider.
|
|